CVE-2021-22813: A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause…
Noroxi assessment
Priority: Monitor (action score 24/100)
- The sources we track (CISA KEV, Exploit-DB, Metasploit, Nuclei, GitHub) show no public exploit code or exploitation in the wild.
- Probability of exploitation in the next 30 days: 0.74% (FIRST EPSS); higher than 55.2% of all records.
- Anyone who can reach it over the internet can trigger it. No account or password is required. A user must open a link or visit a page. No special conditions are required; it is repeatable.
- According to the record, no fixed version is available yet.
- Mentioned 1 time in Turkish national cyber security advisories (siberguvenlik.gov.tr).
Low priority for now. Update when a fix is released; follow the vendor's advisory.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
Primary sources: NVD · CVE.org · FIRST EPSS
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
- Published
- Jan 28, 2022
- Updated
- Jun 16, 2026
- EPSS
- 0.7% · 55th percentile
- CWE
- CWE-79
Report tools
Action score
24
Low priority for now.
- CVSS
- 24 / 40 · 6.1 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.7%
Get told when this record changes
- Not in KEV: no record of exploitation in the wild
- No public exploit code on record
- No fixed version yet
If any of these changes, we'll tell you in the daily email digest.
Limit the impact of XSSCheck security headers
Is your version affected? Check itNoroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| schneider-electric | network management card 2 firmware | cpe:2.3:o:schneider-electric:network_management_card_2_firmware |
| schneider-electric | galaxy 3500 | cpe:2.3:h:schneider-electric:galaxy_3500 |
| schneider-electric | network management card 2 | cpe:2.3:h:schneider-electric:network_management_card_2 |
| schneider-electric | single-phase symmetra | cpe:2.3:h:schneider-electric:single-phase_symmetra |
| schneider-electric | smart-ups | cpe:2.3:h:schneider-electric:smart-ups |
| schneider-electric | ap9922 battery management system | cpe:2.3:h:schneider-electric:ap9922_battery_management_system |
| schneider-electric | apc rack power distribution units | cpe:2.3:h:schneider-electric:apc_rack_power_distribution_units |
| schneider-electric | galaxy g7x | cpe:2.3:h:schneider-electric:galaxy_g7x |
| schneider-electric | galaxy g9kchu | cpe:2.3:h:schneider-electric:galaxy_g9kchu |
| schneider-electric | galaxy gcxsa | cpe:2.3:h:schneider-electric:galaxy_gcxsa |
| schneider-electric | galaxy gfc | cpe:2.3:h:schneider-electric:galaxy_gfc |
| schneider-electric | galaxy gvmsa | cpe:2.3:h:schneider-electric:galaxy_gvmsa |
and 43 more
Limit the impact of XSS
This is a cross-site scripting (XSS) vulnerability. A well-configured Content-Security-Policy doesn't fix it, but greatly reduces its impact. Check your site's CSP and other security headers for free.
Check security headersAffected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- schneider-electric network management card 2 firmwareup to 6.9.8 inclusive
- schneider-electric network management card 2 firmwareup to 6.9.6 inclusive
- schneider-electric network management card 3 firmwareup to 1.4.2.1 inclusive
- schneider-electric network management card 3 firmwareup to 1.4.0 inclusive
Same product
schneider-electric: all recordsOther highest-scoring records for the same primary product.
- CVE-2021-22814A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause…24Monitor
- CVE-2021-22812A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause…24Monitor
- CVE-2021-22811A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script…24Monitor
Published before and after this one in the same product
- ← EarlierCVE-2021-22810Jan 28, 2022 · A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause…24Monitor
- Later →CVE-2021-22815Jan 28, 2022 · A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed.21Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
National notice (Türkiye Cybersecurity Directorate / USOM)
Official security notices citing this record; remediation advice is on the agency's page.
- TR-21-0904 · Nov 10, 2021(Schneider Elektrik Güvenlik Bildirimi)
Not on record for this CVE: EPSS history · patch commit or PR link · researcher credit · variant or chain candidate · public bounty program.
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- No account or password is required.
- A user must open a link or visit a page.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- low · data can be read
- Integrity
- low · data or configuration can be modified
- Availability
- none
Impact can extend beyond the vulnerable component (scope changes).
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- Required
- Scope
- Changed
- Confidentiality impact
- Low
- Integrity impact
- Low
- Availability impact
- None
Weakness class (CWE)
CWE-79 · Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
nvd-primary
Root cause
User content is inserted into the page as HTML. The browser interprets the content as code rather than data.
The bug in code
The whole CWE-79 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
commentEl.innerHTML = comment.body;Fixed
commentEl.textContent = comment.body;Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
ATT&CK techniques
—
Change log (0)
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Vendor advisories and official records. Exploit/PoC links are deliberately left out.