Skip to content
Noroxi

schneider-electric records

789 published records for vendor schneider-electric. 1 of them have been exploited in the wild (listed in CISA KEV) and 3 have a ready-made attack tool.

Filter by product ↓

Researcher profile

Entered KEV
1 · 0.1%
Weaponized
3 · 0.4%
Pre-auth RCE
86
With a fix record
3.9%
Median publish → KEV
1059 days

Pre-auth RCE: flaws that let an attacker run code over the network without an account. Median publish → KEV: the typical time between a record being published and CISA listing it as exploited.

All records

789 records
  • A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an i

    CriticalCVSS 9.8KEVWeaponizedEPSS 72%

    schneider-electric · u.motion builderMay 22, 2019

  • CVE-2019-6814
    60This week

    A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impa

    CriticalCVSS 9.8WeaponizedEPSS 36%

    schneider-electric · net5501 firmwareMay 22, 2019

  • A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlin

    CriticalCVSS 9.8Proof of conceptEPSS 64%

    schneider-electric · evlink city evc1s22p4 firmwareJul 21, 2021

  • A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause r

    HighCVSS 8.8Proof of conceptEPSS 71%

    schneider-electric · spacelogic c-bus home controller firmwareJul 13, 2022

  • A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leadin

    CriticalCVSS 9.8No exploitEPSS 44%

    schneider-electric · interactive graphical scada system data serverFeb 9, 2022

  • A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tamperin

    CriticalCVSS 9.8No exploitEPSS 36%

    schneider-electric · spacelogic c-bus toolkitOct 4, 2023

  • A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Mo

    CriticalCVSS 9.8Proof of conceptEPSS 35%

    schneider-electric · modicon m580 firmwareMay 22, 2019

  • An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could a

    CriticalCVSS 9.8No exploitEPSS 31%

    schneider-electric · iiot monitorDec 24, 2018

  • A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and

    HighCVSS 8.8No exploitEPSS 41%

    schneider-electric · c-bus toolkitApr 13, 2021

  • A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340,

    CriticalCVSS 9.8Proof of conceptEPSS 29%

    schneider-electric · modicon m580 firmwareMay 22, 2019

  • A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and

    HighCVSS 8.8No exploitEPSS 40%

    schneider-electric · c-bus toolkitApr 13, 2021

  • A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Versi

    CriticalCVSS 9.1Proof of conceptEPSS 31%

    schneider-electric · modicon m251 firmwareJun 29, 2017

  • Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to exec

    CriticalCVSS 10.0Proof of conceptEPSS 21%

    schneider-electric · accutech managerFeb 15, 2013

  • Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execut

    CriticalCVSS 10.0Proof of conceptEPSS 21%

    schneider-electric · interactive graphical scada systemJan 21, 2013

  • The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Build

    HighCVSS 8.8Proof of conceptEPSS 31%

    schneider-electric · u.motion builderJul 3, 2018

  • A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length

    CriticalCVSS 9.8No exploitEPSS 20%

    schneider-electric · interactive graphical scada system data collectorFeb 11, 2022

  • A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication mod

    HighCVSS 8.6No exploitEPSS 32%

    schneider-electric · modicon m580 firmwareOct 29, 2019

  • Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to

    CriticalCVSS 9.3Proof of conceptEPSS 22%

    schneider electric · somachineApr 1, 2014

  • An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and p

    CriticalCVSS 9.8No exploitEPSS 13%

    schneider-electric · tableau desktopMar 8, 2017

  • A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a mal

    CriticalCVSS 9.8No exploitEPSS 12%

    schneider-electric · smt series 1015 ups firmwareMar 9, 2022

  • A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code executio

    CriticalCVSS 9.8No exploitEPSS 11%

    schneider-electric · smt series 1015 ups firmwareMar 9, 2022

  • Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScad

    CriticalCVSS 10.0Proof of conceptEPSS 10%

    mitsubishi-automation · mitsubishi mx componentApr 19, 2013

  • Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Ex

    CriticalCVSS 10.0No exploitEPSS 9%

    schneider-electric · stbnic2212 firmwareOct 3, 2014

  • A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of

    CriticalCVSS 9.1No exploitEPSS 21%

    schneider-electric · interactive graphical scada system data collectorFeb 11, 2022

  • A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior.

    CriticalCVSS 9.8No exploitEPSS 9%

    schneider-electric · wonderware archestra loggerJul 7, 2017