CWEAll records
4 records| Action | CVE | Vulnerability | Severity | KEV | EPSS | Published |
|---|---|---|---|---|---|---|
40Plan | CVE-2015-3954No exploit | Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, versionpifzer · plum a\+ infusion system firmware · CWE-285 | Critical9.8 | — | 2.0% | Mar 25, 2019 |
40Plan | CVE-2015-3953No exploit | Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and pifzer · plum a\+ infusion system firmware · CWE-259 | Critical9.8 | — | 2.0% | Mar 25, 2019 |
39Monitor | CVE-2015-3956No exploit | Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, versionpifzer · plum a\+ infusion system firmware · CWE-345 | Critical9.8 | — | 1.0% | Mar 25, 2019 |
30Monitor | CVE-2015-3952No exploit | Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and pifzer · plum a\+ infusion system firmware · CWE-312 | High7.5 | — | 1.0% | Mar 25, 2019 |
- CVE-2015-395440Plan
Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version
CriticalCVSS 9.8No exploitEPSS 2%pifzer · plum a\+ infusion system firmwareMar 25, 2019
- CVE-2015-395340Plan
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and
CriticalCVSS 9.8No exploitEPSS 2%pifzer · plum a\+ infusion system firmwareMar 25, 2019
- CVE-2015-395639Monitor
Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version
CriticalCVSS 9.8No exploitEPSS 1%pifzer · plum a\+ infusion system firmwareMar 25, 2019
- CVE-2015-395230Monitor
Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and
HighCVSS 7.5No exploitEPSS 1%pifzer · plum a\+ infusion system firmwareMar 25, 2019