Skip to content
Noroxi

hitachienergy records

111 published records for vendor hitachienergy. 0 of them have been exploited in the wild (listed in CISA KEV) and 1 have a ready-made attack tool.

Filter by product ↓

Researcher profile

Entered KEV
0 · 0%
Weaponized
1 · 0.9%
Pre-auth RCE
1
With a fix record
0.9%
Median publish → KEV
No record has entered KEV

Pre-auth RCE: flaws that let an attacker run code over the network without an account. Median publish → KEV: the typical time between a record being published and CISA listing it as exploited.

All records

111 records
  • CVE-2019-5620
    60This week

    ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function

    CriticalCVSS 9.8WeaponizedEPSS 70%

    hitachienergy · microscada pro sys600Apr 29, 2020

  • An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.1

    CriticalCVSS 10.0No exploitEPSS 1%

    hitachienergy · relion 670 firmwareNov 27, 2019

  • ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key val

    CriticalCVSS 9.8No exploitEPSS 4%

    hitachienergy · esomsAug 29, 2018

  • An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers withou

    CriticalCVSS 10.0No exploitEPSS 0%

    hitachienergy · foxman-unJun 11, 2024

  • CVE-2022-3927
    39Monitor

    The affected products store public and private key that are used to sign and protect custom parameter set files from modification.

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · foxman-unJan 5, 2023

  • CVE-2024-2012
    39Monitor

    vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or cod

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · foxman-unJun 11, 2024

  • CVE-2024-7940
    39Monitor

    The product exposes a service that is intended for local only to all network interfaces without any authentication.

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · microscada x sys600Aug 27, 2024

  • CVE-2024-2011
    39Monitor

    A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · foxman-unJun 11, 2024

  • CVE-2022-3929
    39Monitor

    Communication between the client and server partially using CORBA over TCP/IP

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · foxman-unJan 5, 2023

  • Use of default key for encryption

    CriticalCVSS 9.8No exploitEPSS 0%

    hitachienergy · foxman-unJan 5, 2023

  • CVE-2022-3686
    36Monitor

    SDM600 API permission check

    CriticalCVSS 9.1No exploitEPSS 1%

    hitachienergy · sdm600Mar 28, 2023

  • CVE-2022-3682
    35Monitor

    SDM600 file permission validation

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · sdm600Mar 28, 2023

  • An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (includi

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · ellipseDec 20, 2017

  • A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authentica

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · microscada x sys600Sep 12, 2022

  • CVE-2024-3980
    35Monitor

    The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesyst

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · microscada pro sys600Aug 27, 2024

  • CVE-2023-4816
    35Monitor

    A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214.

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · asset suiteSep 11, 2023

  • CVE-2024-4872
    35Monitor

    A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product.

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · microscada pro sys600Aug 27, 2024

  • HTTP Response Splitting in Hitachi Energy’s MSM Product

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · modular switchgear monitoring firmwareJul 25, 2022

  • Cross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product

    HighCVSS 8.8No exploitEPSS 0%

    hitachienergy · modular switchgear monitoring firmwareJul 25, 2022

  • CVE-2026-1773
    34Monitor

    IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame.

    HighCVSS 8.7No exploitEPSS 0%

    hitachienergy · rtu540 firmwareFeb 24, 2026

  • A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product.

    HighCVSS 8.5No exploitEPSS 0%

    hitachienergy · microscada x sys600Jun 24, 2025

  • CVE-2026-9853
    34Monitor

    A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read a

    HighCVSS 8.5No exploitEPSS 0%

    hitachienergy · microscada x sys600Sep 3, 2026

  • CVE-2026-9854
    34Monitor

    A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to adminis

    HighCVSS 8.5No exploitEPSS 0%

    hitachienergy · microscada x sys600Sep 3, 2026

  • A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product.

    HighCVSS 8.3No exploitEPSS 0%

    hitachienergy · microscada x sys600Jun 24, 2025

  • Insufficient Security Control Vulnerability

    HighCVSS 8.1No exploitEPSS 0%

    hitachienergy · relion 670 firmwareNov 18, 2021