carel records
11 published records for vendor carel.
Researcher profile
- Entered KEV
- 0 · 0%
- Weaponized
- 0 · 0%
- Pre-auth RCE
- 0
- With a fix record
- 0%
- Median publish → KEV
- No record has entered KEV
Pre-auth RCE: flaws that let an attacker run code over the network without an account. Median publish → KEV: the typical time between a record being published and CISA listing it as exploited.
Recurring classes
- CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')2
- CWE-306 Missing Authentication for Critical Function2
- CWE-284 Improper Access Control1
- CWE-522 Insufficiently Protected Credentials1
- CWE-73 External Control of File Name or Path1
- CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')1
The weakness classes this vendor ships most often: where to look.
CWEAll records
11 records| Action | CVE | Vulnerability | Severity | EPSS · Published |
|---|---|---|---|---|
62This week | CVE-2023-3643Proof of concept | Boss Mini document file inclusioncarel · boss mini firmware · CWE-73 | Critical9.8 | 75.3%Jul 12, 2023 |
40Plan | CVE-2019-13553No exploit | Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4.carel · pcoweb firmware · CWE-798 | Critical9.8 | 2.2%Oct 25, 2019 |
39Monitor | CVE-2022-34827No exploit | Carel Boss Mini 1.5.0 has Improper Access Control.carel · boss mini firmware · CWE-284 | Critical9.9 | 0.9%Nov 18, 2022 |
37Monitor | CVE-2022-37122Proof of concept | Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unautcarel · pcoweb card firmware · CWE-22 | High7.5 | 23.5%Aug 31, 2022 |
37Monitor | CVE-2019-11369Proof of concept | An issue was discovered in Carel pCOWeb prior to B1.2.4.carel · pcoweb card firmware · CWE-522 | High8.8 | 8.1%Jun 3, 2019 |
31Monitor | CVE-2016-0867No exploit | CAREL PlantVisorEnhanced allows remote attackers to bypass intended access restrictions via a direct file request.carel · plantvisor enhanced · CWE-200 | High7.5 | 2.1%Jan 30, 2016 |
30Monitor | CVE-2019-9484No exploit | The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTPcarel · pcoweb card firmware · CWE-306 | High7.5 | 1.5%Mar 1, 2019 |
30Monitor | CVE-2019-13549No exploit | Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4.carel · pcoweb firmware · CWE-306 | High7.5 | 1.0%Oct 25, 2019 |
30Monitor | CVE-2020-18329No exploit | An issue was discovered in Rehau devices that use a pCOWeb card BIOS v6.27, BOOT v5.00, web version v2.2, allows attackers to gain full unaucarel · pcoweb card web · CWE-281 | High7.5 | 0.9%Jan 26, 2023 |
22Monitor | CVE-2011-3487Proof of concept | Directory traversal vulnerability in CarelDataServer.exe in Carel PlantVisor 2.4.4 and earlier allows remote attackers to read arbitrary filcarel · plantvisor · CWE-22 | Medium5.0 | 7.4%Sep 16, 2011 |
22Monitor | CVE-2019-11370Proof of concept | Stored XSS was discovered in Carel pCOWeb prior to B1.2.4, as demonstrated by the config/pw_snmp.html "System contact" field.carel · pcoweb card firmware · CWE-79 | Medium5.4 | 4.4%Jun 3, 2019 |
- CVE-2023-364362This week
Boss Mini document file inclusion
CriticalCVSS 9.8Proof of conceptEPSS 75%carel · boss mini firmwareJul 12, 2023
- CVE-2019-1355340Plan
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4.
CriticalCVSS 9.8No exploitEPSS 2%carel · pcoweb firmwareOct 25, 2019
- CVE-2022-3482739Monitor
Carel Boss Mini 1.5.0 has Improper Access Control.
CriticalCVSS 9.9No exploitEPSS 0%carel · boss mini firmwareNov 18, 2022
- CVE-2022-3712237Monitor
Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unaut
HighCVSS 7.5Proof of conceptEPSS 23%carel · pcoweb card firmwareAug 31, 2022
- CVE-2019-1136937Monitor
An issue was discovered in Carel pCOWeb prior to B1.2.4.
HighCVSS 8.8Proof of conceptEPSS 8%carel · pcoweb card firmwareJun 3, 2019
- CVE-2016-086731Monitor
CAREL PlantVisorEnhanced allows remote attackers to bypass intended access restrictions via a direct file request.
HighCVSS 7.5No exploitEPSS 2%carel · plantvisor enhancedJan 30, 2016
- CVE-2019-948430Monitor
The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTP
HighCVSS 7.5No exploitEPSS 1%carel · pcoweb card firmwareMar 1, 2019
- CVE-2019-1354930Monitor
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4.
HighCVSS 7.5No exploitEPSS 1%carel · pcoweb firmwareOct 25, 2019
- CVE-2020-1832930Monitor
An issue was discovered in Rehau devices that use a pCOWeb card BIOS v6.27, BOOT v5.00, web version v2.2, allows attackers to gain full unau
HighCVSS 7.5No exploitEPSS 0%carel · pcoweb card webJan 26, 2023
- CVE-2011-348722Monitor
Directory traversal vulnerability in CarelDataServer.exe in Carel PlantVisor 2.4.4 and earlier allows remote attackers to read arbitrary fil
MediumCVSS 5.0Proof of conceptEPSS 7%carel · plantvisorSep 16, 2011
- CVE-2019-1137022Monitor
Stored XSS was discovered in Carel pCOWeb prior to B1.2.4, as demonstrated by the config/pw_snmp.html "System contact" field.
MediumCVSS 5.4Proof of conceptEPSS 4%carel · pcoweb card firmwareJun 3, 2019