CVE-2026-31981: HTML injection in Diagram tab and Graph view in Guardian/CMC before 26.2.0
Noroxi assessment
Priority: Monitor (action score 19/100)
- The sources we track (CISA KEV, Exploit-DB, Metasploit, Nuclei, GitHub) show no public exploit code or exploitation in the wild.
- Probability of exploitation in the next 30 days: 0.25% (FIRST EPSS).
- Anyone who can reach it over the internet can trigger it. Administrator privileges are required. No special conditions are required; it is repeatable.
- Fixed version: Nozomi Networks CMC 26.2.0; Nozomi Networks Guardian 26.2.0.
Low priority for now. Upgrade to Nozomi Networks CMC 26.2.0; Nozomi Networks Guardian 26.2.0 or later.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
Primary sources: NVD · CVE.org · FIRST EPSS
A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
- Published
- Jul 9, 2026
- Updated
- Aug 11, 2026
- EPSS
- 0.2% · 16th percentile
- CWE
- CWE-79
Report tools
Action score
19
Low priority for now.
- CVSS
- 19 / 40 · 4.8 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.2%
CISA SSVC decision
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
Vulnrichment: CISA's decision-tree inputs.
CNA vs NVD score
- NVD
- —
- CNA · Nozomi
- 4.8
- NVD has not scored this yet; the score shown is the CNA’s.
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L
The score given by the assigning authority versus NVD’s independent score. A gap means the severity is contested.
Get told when this record changes
- Not in KEV: no record of exploitation in the wild
- No public exploit code on record
- A fix has been released
If any of these changes, we'll tell you in the daily email digest.
Limit the impact of XSSCheck security headers
Is your version affected? Check itNoroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| nozominetworks | cmc | cpe:2.3:a:nozominetworks:cmc |
| nozominetworks | guardian | cpe:2.3:a:nozominetworks:guardian |
Limit the impact of XSS
This is a cross-site scripting (XSS) vulnerability. A well-configured Content-Security-Policy doesn't fix it, but greatly reduces its impact. Check your site's CSP and other security headers for free.
Check security headersVersions reported by the vendor
Affected version ranges reported by the assigning authority (Nozomi). Independent of NVD's CPE analysis and usually ahead of it.
Nozomi Networks CMC
- before 26.2.0affected · semver
Nozomi Networks Guardian
- before 26.2.0affected · semver
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- nozominetworks cmcbefore 26.2.0
- nozominetworks guardianbefore 26.2.0
Same product
nozominetworks: all recordsOther highest-scoring records for the same primary product.
- CVE-2023-29245SQL Injection on IDS parsing of malformed asset fields in Guardian/CMC >= 22.6.0 before 22.6.3 and 23.1.036Monitor
- CVE-2026-31984DoS through oversized audit log entries in Guardian/CMC before 26.2.034Monitor
- CVE-2023-2567Authenticated SQL Injection on Query functionality in Guardian/CMC before 22.6.3 and 23.1.034Monitor
Published before and after this one in the same product
- ← EarlierCVE-2025-40903May 19, 2026 · HTML injection in Schedule Restore Archive in Guardian/CMC before 26.1.019Monitor
- ← EarlierCVE-2025-40904May 19, 2026 · HTML injection in Smart Polling in Guardian/CMC before 26.1.020Monitor
- Later →CVE-2026-31982Jul 9, 2026 · Open Redirect in SAML Single Sign-On in Guardian/CMC before 26.2.021Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
| Product / package | Fixed version | Source |
|---|---|---|
| Nozomi Networks CMC | 26.2.0 | Vendor (CNA) |
| Nozomi Networks Guardian | 26.2.0 | Vendor (CNA) |
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
- Stefano Libero and Andrea PalancaNozomi Networks Product Security team during an internal investigation.finder
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
- CVE-2025-40892203 days apartStored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.028Monitor
- CVE-2025-40893203 days apartHTML injection in Asset List in Guardian/CMC before 25.5.021Monitor
- CVE-2025-4090451 days apartHTML injection in Smart Polling in Guardian/CMC before 26.1.020Monitor
- CVE-2025-4090151 days apartHTML injection in Credentials Manager in Guardian/CMC before 26.1.019Monitor
- CVE-2025-4090251 days apartHTML injection in Users in Guardian/CMC before 26.1.019Monitor
- CVE-2025-4090351 days apartHTML injection in Schedule Restore Archive in Guardian/CMC before 26.1.019Monitor
Not on record for this CVE: EPSS history · patch commit or PR link · public bounty program.
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- Administrator privileges are required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- Integrity
- Availability
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- High
- User interaction
- P
- Scope
- X
Weakness class (CWE)
CWE-79 · Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
nvd-secondary
Root cause
User content is inserted into the page as HTML. The browser interprets the content as code rather than data.
The bug in code
The whole CWE-79 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
commentEl.innerHTML = comment.body;Fixed
commentEl.textContent = comment.body;Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
ATT&CK techniques
—
Change log (1)
- Fix✗ → ✓
For records you follow, these changes also arrive as notifications. →
References
Show all references (1 more)Show less
Vendor advisories and official records. Exploit/PoC links are deliberately left out.