CVE-2020-7580: A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1
Noroxi assessment
Priority: Monitor (action score 26/100)
- The sources we track (CISA KEV, Exploit-DB, Metasploit, Nuclei, GitHub) show no public exploit code or exploitation in the wild.
- Probability of exploitation in the next 30 days: 0.46% (FIRST EPSS).
- Someone with local access to the system can trigger it. Administrator privileges are required. No user action is required. No special conditions are required; it is repeatable.
- According to the record, no fixed version is available yet.
- Mentioned 1 time in Turkish national cyber security advisories (siberguvenlik.gov.tr).
Low priority for now. Update when a fix is released; follow the vendor's advisory.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
Primary sources: NVD · CVE.org · FIRST EPSS
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
- Published
- Jun 10, 2020
- Updated
- Jun 16, 2026
- EPSS
- 0.4% · 39th percentile
- CWE
- CWE-428
Report tools
Action score
26
Monitor
Low priority for now.
- CVSS
- 26 / 40 · 6.7 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.4%
Get told when this record changes
- Not in KEV: no record of exploitation in the wild
- No public exploit code on record
- No fixed version yet
If any of these changes, we'll tell you in the daily email digest.
Running WordPress? Scan your site free with WP Lens
Noroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| siemens | simatic automatic tool | cpe:2.3:a:siemens:simatic_automatic_tool |
| siemens | simatic net pc | cpe:2.3:a:siemens:simatic_net_pc |
| siemens | simatic pcs 7 | cpe:2.3:a:siemens:simatic_pcs_7 |
| siemens | simatic pcs neo | cpe:2.3:a:siemens:simatic_pcs_neo |
| siemens | simatic prosave | cpe:2.3:a:siemens:simatic_prosave |
| siemens | simatic s7-1500 software controller | cpe:2.3:a:siemens:simatic_s7-1500_software_controller |
| siemens | simatic step 7 | cpe:2.3:a:siemens:simatic_step_7 |
| siemens | simatic wincc | cpe:2.3:a:siemens:simatic_wincc |
| siemens | simatic wincc open architecture | cpe:2.3:a:siemens:simatic_wincc_open_architecture |
| siemens | simatic wincc runtime advanced | cpe:2.3:a:siemens:simatic_wincc_runtime_advanced |
| siemens | simatic wincc runtime professional | cpe:2.3:a:siemens:simatic_wincc_runtime_professional |
| siemens | sinamics startdrive | cpe:2.3:a:siemens:sinamics_startdrive |
and 5 more
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- siemens simatic automatic toolall versions
- siemens simatic net pcbefore 16
- siemens simatic net pc16
- siemens simatic pcs 7all versions
- siemens simatic pcs neoall versions
- siemens simatic prosaveall versions
- siemens simatic s7-1500 software controllerbefore 21.8
- siemens simatic step 7before 5.6
- siemens simatic step 713 and later · up to 16 inclusive
- siemens simatic step 75.6
- siemens simatic winccbefore 7.4
- siemens simatic wincc7.4
- siemens simatic wincc7.5
- siemens simatic wincc open architecture3.16
- siemens simatic wincc open architecture3.17
- siemens simatic wincc runtime advancedall versions
- siemens simatic wincc runtime professional13 and later · up to 16 inclusive
- siemens sinamics startdriveall versions
- siemens sinamics starter commissioning toolall versions
- siemens sinec network management systemall versions
Versions reported by the vendor
Affected version ranges reported by the assigning authority (siemens). Independent of NVD's CPE analysis and usually ahead of it.
Siemens SIMATIC Automation Tool
- All versions < V4 SP2affected
Siemens SIMATIC NET PC Software V14
- All versions < V14 SP1 Update 14affected
Siemens SIMATIC NET PC Software V15
- All versionsaffected
Siemens SIMATIC NET PC Software V16
- All versions < V16 Upd3affected
Siemens SIMATIC PCS neo
- All versions < V3.0 SP1affected
Siemens SIMATIC ProSave
- All versions < V17affected
Siemens SIMATIC S7-1500 Software Controller
- All versions < V21.8affected
Siemens SIMATIC STEP 7 (TIA Portal) V13
- All versions < V13 SP2 Update 4affected
Siemens SIMATIC STEP 7 (TIA Portal) V14
- All versions < V14 SP1 Update 10affected
Siemens SIMATIC STEP 7 (TIA Portal) V15
- All versions < V15.1 Update 5affected
Siemens SIMATIC STEP 7 (TIA Portal) V16
- All versions < V16 Update 2affected
Siemens SIMATIC STEP 7 V5
- All versions < V5.6 SP2 HF3affected
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
No history yet (it accumulates with the daily EPSS job).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
No credits in the CNA record.
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
No nightly-computed relations.
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
—
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
National notice (Türkiye Cybersecurity Directorate / USOM)
Official security notices citing this record; remediation advice is on the agency's page.
- TR-20-416 · Jun 10, 2020(Siemens Endüstriyel Ürünler Zafiyeti)
Technical details
Attack conditions
- Someone with local access to the system can trigger it.
- Administrator privileges are required.
- No user action is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- high · data can be read
- Integrity
- high · data or configuration can be modified
- Availability
- high · the service can be disrupted
- Attack vector
- Local
- Attack complexity
- Low
- Privileges required
- High
- User interaction
- None
- Scope
- Unchanged
- Confidentiality impact
- High
- Integrity impact
- High
- Availability impact
- High
Weakness class (CWE)
CWE-428 · Unquoted Search Path or ElementCVSS vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
nvd-primary
Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
MITRE has no CAPEC/ATT&CK mapping for this CWE.
Change log
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Show all references (1 more)Show less
Vendor advisories and official records. Exploit/PoC links are deliberately left out.