CVE-2018-14558: An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318…
Noroxi assessment
Priority: This week (action score 72/100)
- CISA has confirmed exploitation in the wild (Nov 3, 2021). Remediation deadline for US federal agencies: May 3, 2022.
- Probability of exploitation in the next 30 days: 8.5% (FIRST EPSS); higher than 95.1% of all records.
- Anyone who can reach it over the internet can trigger it. No account or password is required. No user action is required. No special conditions are required; it is repeatable.
- According to CISA the attack is automatable: targets can be found by mass scanning.
- According to the record, no fixed version is available yet.
Don’t wait for the next maintenance window. Until a fix is released, restrict access to the affected component and follow the vendor's advisory.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
Primary sources: NVD · CVE.org · CISA KEV · FIRST EPSS
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
- Published
- Oct 30, 2018
- Updated
- Jun 16, 2026
- EPSS
- 8.5% · 95th percentile
- CWE
- CWE-78
Report tools
Action score
72
Don’t wait for the next maintenance window.
- CVSS
- 39 / 40 · 9.8 / 10
- CISA KEV
- 30 / 30 · Listed
- EPSS
- 3 / 30 · 8.5%
CISA SSVC decision
- Exploitation
- active
- Automatable
- yes
- Technical impact
- total
Vulnrichment: CISA's decision-tree inputs.
Actively exploited in the wild
CISA added this to its Known Exploited Vulnerabilities catalog on Nov 3, 2021. That signals real attacks, not theory.
Remediation deadline for US federal agencies: May 3, 2022.
Get told when this record changes
- In CISA KEV: exploitation in the wild confirmed
- Weaponized exploit exists
- No fixed version yet
If any of these changes, we'll tell you in the daily email digest.
Is your version affected? Check itNoroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| tenda | ac7 firmware | cpe:2.3:o:tenda:ac7_firmware |
| tenda | ac7 | cpe:2.3:h:tenda:ac7 |
| tenda | ac9 firmware | cpe:2.3:o:tenda:ac9_firmware |
| tenda | ac9 | cpe:2.3:h:tenda:ac9 |
| tenda | ac10 firmware | cpe:2.3:o:tenda:ac10_firmware |
| tenda | ac10 | cpe:2.3:h:tenda:ac10 |
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- tenda ac10 firmwareup to 15.03.06.23_cn inclusive
- tenda ac7 firmwareup to 15.03.06.44_cn inclusive
- tenda ac9 firmwareup to 15.03.05.19\(6318\)_cn inclusive
Same product
tenda: all recordsOther highest-scoring records for the same primary product.
- CVE-2026-51846In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can…39Monitor
- CVE-2026-51845Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.39Monitor
- CVE-2026-51844Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.39Monitor
Published before and after this one in the same product
- ← EarlierCVE-2018-18731Oct 29, 2018 · An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18…30Monitor
- ← EarlierCVE-2018-18732Oct 29, 2018 · An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18…30Monitor
- Later →CVE-2018-14557Apr 25, 2019 · An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through…30Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
Weaponized
A ready exploit tool or active in-the-wild use is known for this vulnerability. This should be your top priority.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
- Published
- CISA KEV+1099 d
- TodayNov 16, 2026+2939 d
Not on record for this CVE: EPSS history · patch commit or PR link · researcher credit · variant or chain candidate · public bounty program.
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- No account or password is required.
- No user action is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- high · data can be read
- Integrity
- high · data or configuration can be modified
- Availability
- high · the service can be disrupted
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality impact
- High
- Integrity impact
- High
- Availability impact
- High
Weakness class (CWE)
CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd-primary
Root cause
User input is inserted as text into a shell command. The shell may interpret special characters in the input as part of the command.
The bug in code
The whole CWE-78 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
const host = req.body.host;
exec("ping -c 1 " + host, onResult);Fixed
const host = req.body.host;
if (!/^[a-z0-9.-]{1,253}$/i.test(host)) return res.sendStatus(400);
execFile("ping", ["-c", "1", host], onResult);Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
- Command Line Execution through SQL InjectionCAPEC-108likelihood: Low · Very High
- Command DelimitersCAPEC-15likelihood: High · High
- Exploiting Multiple Input Interpretation LayersCAPEC-43likelihood: Medium · High
- Argument InjectionCAPEC-6likelihood: High · High
- OS Command InjectionCAPEC-88likelihood: High · High
ATT&CK techniques
—
Change log (0)
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Vendor advisories and official records. Exploit/PoC links are deliberately left out.