Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malform

Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the Server Icon.

HighCVSS 7.5 · v3.0—No exploit No fix recorded
Published
Sep 25, 2017
Updated
Jun 16, 2026
EPSS
1.0% · 62th percentile
Follow this CVE

Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.

Report tools

JSON

Action score

30

Monitor

Low priority for now.

CVSS
30 / 40 · 7.5 / 10
CISA KEV
0 / 30 · Not listed
EPSS
0 / 30 · 1.0%

Affected systems

VendorProduct
avevaclearscada

Affected versions

NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.

  • aveva clearscadaup to 2010 inclusive

Versions reported by the vendor

Affected version ranges reported by the assigning authority (schneider). Independent of NVD's CPE analysis and usually ahead of it.

  • Schneider Electric SE ClearSCADA

    • 2017, 2015 R2, 2015 R1.1, 2015 R1 and all prior versionsaffected

Other highest-scoring records for the same primary product.

  • CVE-2011-3143Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and
    42Plan
  • CVE-2017-6021In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior,
    31Monitor
  • CVE-2014-0779Schneider Electric StruxureWare SCADA Expert ClearSCADA Improper Restriction of Operations within the Bounds of a Memory Buffer
    27Monitor
  • CVE-2014-5413Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues
    20Monitor
  • CVE-2014-5412Schneider Electric SCADA Expert ClearSCADA Improper Authentication
    20Monitor
  • CVE-2011-3144Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before
    18Monitor

Remediation

Which version to upgrade to

Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.

No fix version is recorded for this entry. Check the references for vendor advisories.

Exploit status

No known public exploit

No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.

Research context

For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.

Timeline

From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.

No dated events beyond publication.

EPSS, last 120 days

FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).

Patch and commit links

Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.

No commit or PR link among the references.

Finders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.

No credits in the CNA record.

Variant candidates

Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.

No nightly-computed relations.

Chain candidates

An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.

—

Bug bounty scope

No known public program.

Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).

Technical details

Attack conditions

  • Anyone who can reach it over the internet can trigger it.
  • No account or password is required.
  • No user action is required.
  • No special conditions are required; it is repeatable.

If successful

Confidentiality
none
Integrity
none
Availability
high · the service can be disrupted
Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality impact
None
Integrity impact
None
Availability impact
High

CVSS vector

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

nvd-primary

Noroxi analysis

No Noroxi analysis for this record yet

We don't hand-write analysis for all 385,000+ vulnerabilities; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.

We use this product, ask for help

Change log

No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.

References

Vendor advisories and official records. Exploit/PoC links are deliberately left out.

All records