Skip to content
Noroxi
CVE-2017-9942· NVD / CVE Program· CNA siemens

A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to th

A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems.

HighCVSS 7.8 · v3.0—No exploit No fix recorded
Published
Aug 7, 2017
Updated
Jun 16, 2026
EPSS
0.3% · 18th percentile
Follow this CVE

Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.

Report tools

JSON

Action score

31

Monitor

Low priority for now.

CVSS
31 / 40 · 7.8 / 10
CISA KEV
0 / 30 · Not listed
EPSS
0 / 30 · 0.3%

Affected systems

VendorProduct
siemenssipass integrated

Affected versions

NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.

  • siemens sipass integratedup to 2.65 inclusive

Versions reported by the vendor

Affected version ranges reported by the assigning authority (siemens). Independent of NVD's CPE analysis and usually ahead of it.

  • n/a SiPass integrated All versions before V2.70

    • SiPass integrated All versions before V2.70affected

Other highest-scoring records for the same primary product.

  • CVE-2012-5409AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethe
    45Plan
  • CVE-2017-9939A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to
    40Plan
  • CVE-2021-44524A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.
    39Monitor
  • CVE-2021-44523A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.
    36Monitor
  • CVE-2022-31812A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18).
    34Monitor
  • CVE-2017-9940A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-pr
    32Monitor

Remediation

Which version to upgrade to

Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.

No fix version is recorded for this entry. Check the references for vendor advisories.

Exploit status

No known public exploit

No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.

Research context

For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.

Timeline

From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.

No dated events beyond publication.

EPSS, last 120 days

FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).

Patch and commit links

Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.

No commit or PR link among the references.

Finders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.

No credits in the CNA record.

Variant candidates

Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.

No nightly-computed relations.

Chain candidates

An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.

—

Bug bounty scope

No known public program.

Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).

Technical details

Attack conditions

  • Someone with local access to the system can trigger it.
  • A low-privileged account is enough.
  • No user action is required.
  • No special conditions are required; it is repeatable.

If successful

Confidentiality
high · data can be read
Integrity
high · data or configuration can be modified
Availability
high · the service can be disrupted
Attack vector
Local
Attack complexity
Low
Privileges required
Low
User interaction
None
Scope
Unchanged
Confidentiality impact
High
Integrity impact
High
Availability impact
High

CVSS vector

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

nvd-primary

Attack context

MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.

Noroxi analysis

No Noroxi analysis for this record yet

We don't hand-write analysis for all 385,000+ vulnerabilities; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.

We use this product, ask for help

Change log

No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.

References

Vendor advisories and official records. Exploit/PoC links are deliberately left out.

All records