Vasion Print (formerly PrinterLogic) Blind SSRF via Lexmark dellCheck.php
Noroxi assessment
Priority: Monitor (action score 27/100)
- The sources we track (CISA KEV, Exploit-DB, Metasploit, Nuclei, GitHub) show no public exploit code or exploitation in the wild.
- Probability of exploitation in the next 30 days: 0.55% (FIRST EPSS).
- Anyone who can reach it over the internet can trigger it. No account or password is required. No user action is required. No special conditions are required; it is repeatable.
- According to CISA the attack is automatable: targets can be found by mass scanning.
- Fixed version: Vasion Print Application 25.1.1413; Vasion Print Virtual Appliance Host 25.1.102.
Low priority for now. Upgrade to Vasion Print Application 25.1.1413; Vasion Print Virtual Appliance Host 25.1.102 or later.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
Primary sources: NVD · CVE.org · FIRST EPSS
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 25.1.1413 (VA/SaaS deployments) contain a blind server-side request forgery (SSRF) vulnerability reachable via the /var/www/app/console_release/lexmark/dellCheck.php script that can be exploited by an unauthenticated user. When a printer is registered, the software stores the printer’s host name in the variable $printer_vo->str_host_address. The code later builds a URL like 'http://<host‑address>:80/DevMgmt/DiscoveryTree.xml' and sends the request with curl. No validation, whitelist, or private‑network filtering is performed before the request is made. Because the request is blind, an attacker cannot see the data directly, but can still: probe internal services, trigger internal actions, or gather other intelligence. This vulnerability has been confirmed to be remediated, but it is unclear as to when the patch was introduced.
- Published
- Sep 29, 2025
- Updated
- Jun 17, 2026
- EPSS
- 0.6% · 45th percentile
- CWE
- CWE-306
Report tools
Action score
27
Monitor
Low priority for now.
- CVSS
- 27 / 40 · 6.9 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.6%
CISA SSVC decision
- Exploitation
- proof of concept
- Automatable
- yes
- Technical impact
- partial
Vulnrichment: CISA's decision-tree inputs.
CNA vs NVD score
- NVD
- —
- CNA · VulnCheck
- 6.9
- NVD has not scored this yet; the score shown is the CNA’s.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
The score given by the assigning authority versus NVD’s independent score. A gap means the severity is contested.
Get told when this record changes
- Not in KEV: no record of exploitation in the wild
- No public exploit code on record
- A fix has been released
If any of these changes, we'll tell you in the daily email digest.
Running WordPress? Scan your site free with WP Lens
Noroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| vasion | virtual appliance application | cpe:2.3:a:vasion:virtual_appliance_application |
| vasion | virtual appliance host | cpe:2.3:a:vasion:virtual_appliance_host |
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- vasion virtual appliance applicationbefore 25.1.1413
- vasion virtual appliance hostbefore 25.1.102
Versions reported by the vendor
Affected version ranges reported by the assigning authority (VulnCheck). Independent of NVD's CPE analysis and usually ahead of it.
Vasion Print Application
- before 25.1.1413affected · semver
Vasion Print Virtual Appliance Host
- before 25.1.102affected · semver
Same product
vasion: all recordsOther highest-scoring records for the same primary product.
- CVE-2025-34217Vasion Print (formerly PrinterLogic) Undocumented Hardcoded SSH Key40Plan
- CVE-2025-34224Vasion Print (formerly PrinterLogic) Unauthenticated Device Modification40Plan
- CVE-2025-34223Vasion Print (formerly PrinterLogic) Insecure Installation Credentials40Plan
- CVE-2025-34222Vasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates40Plan
- CVE-2025-34221Vasion Print (formerly PrinterLogic)40Plan
- CVE-2025-34218Vasion Print (formerly PrinterLogic) Exposed Internal Docker Instance40Plan
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
| Product / package | Fixed version | Source |
|---|---|---|
| Vasion Print Application | 25.1.1413 | Vendor (CNA) |
| Vasion Print Virtual Appliance Host | 25.1.102 | Vendor (CNA) |
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
- Pierre Barrefinder
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
- CVE-2025-342160 days apartVasion Print (formerly PrinterLogic) RCE and Password Leaks via API40Plan
- CVE-2025-342180 days apartVasion Print (formerly PrinterLogic) Exposed Internal Docker Instance40Plan
- CVE-2025-342210 days apartVasion Print (formerly PrinterLogic)40Plan
- CVE-2025-342220 days apartVasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates40Plan
- CVE-2025-342230 days apartVasion Print (formerly PrinterLogic) Insecure Installation Credentials40Plan
- CVE-2025-342240 days apartVasion Print (formerly PrinterLogic) Unauthenticated Device Modification40Plan
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
- CVE-2025-342150 days apartVasion Print (formerly PrinterLogic) Unauthenticated Firmware Update Endpoint RCE37Monitor
- CVE-2025-342330 days apartVasion Print (formerly PrinterLogic) Insecure Use of file_get_contents()34Monitor
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- No account or password is required.
- No user action is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- Integrity
- Availability
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- None
- Scope
- X
Weakness class (CWE)
CWE-306 · Missing Authentication for Critical FunctionCVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
nvd-secondary
Root cause
A function added for development or support ships to production without authentication. It often relies on the assumption that it is “only reachable from the internal network.”
The bug in code
The whole CWE-306 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
// Added for the support teamapp.post("/maintenance/reset", resetDevice);Fixed
if (config.maintenanceEnabled) { app.post( "/maintenance/reset", requireSession, requireRole("admin"), resetDevice );}Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
ATT&CK techniques
—
Change log
- Fix✗ → ✓
For records you follow, these changes also arrive as notifications. →
References
Show all references (2 more)Show less
Vendor advisories and official records. Exploit/PoC links are deliberately left out.