İçeriğe atla
Noroxi
CVE-2024-43659· NVD / CVE Programı· CNA DIVD

Plaintext default credentials in firmware

After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

YüksekCVSS 8.3 · v4.0—İstismar yok Düzeltme kaydı yok
Yayın
9 Oca 2025
Güncelleme
17 Haz 2026
EPSS
%0,8 · 57. yüzdelik
Bu CVE’yi takip et

Takip etmek için giriş yap · Takip ettiğin kayıt KEV’e girer, istismarı çıkar ya da güncellenirse bildirim alırsın.

Rapor araçları

JSON

Aksiyon skoru

33

İzleyin

Şimdilik düşük öncelik.

CVSS
33 / 40 · 8.3 / 10
CISA KEV
0 / 30 · Listede değil
EPSS
0 / 30 · %0,8

CISA SSVC kararı

Sömürü
yok
Otomatikleştirilebilir
hayır
Teknik etki
tam

Vulnrichment: CISA'nın karar ağacı girdileri.

CNA ile NVD puanı

NVD
—
CNA · DIVD
8,3
NVD henüz kendi puanını vermedi; gösterilen puan CNA’nın.

CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/S:P/AU:N

Kaydı açan otoritenin puanı ile NVD’nin bağımsız puanı. İki puan arasındaki fark ciddiyetin tartışmalı olduğunu gösterir.

Noroxi analizi

Bu kayıt için henüz Noroxi analizi yok

Veritabanındaki yüz binlerce zafiyetin tamamına elle analiz yazmıyoruz; bu dürüst olmazdı. Öne çıkan ve sahada etkisi olan zafiyetler için mekanizma, tespit ve kapatma adımlarını ekibimiz yazıyor.

Bu ürünü kullanıyoruz, yardım isteyin

Etkilenen sistemler

—

Üreticinin bildirdiği sürümler

Kaydı açan otorite (DIVD) tarafından bildirilen etkilenen sürüm aralıkları. NVD'nin CPE analizinden bağımsızdır ve genellikle ondan önce gelir.

  • Iocharger Iocharger firmware for AC models

    • 25010801 öncesietkilenir

Aynı birincil ürünün en yüksek skorlu diğer kayıtları.

  • CVE-2024-43654Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station
    38İzleyin
  • CVE-2024-43653Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station
    38İzleyin
  • CVE-2024-43651Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station
    38İzleyin
  • CVE-2024-43649Authenticated command injection via <redacted>.exe <redacted> parameter
    38İzleyin
  • CVE-2024-43648Authenticated command injection via <redacted>.exe <redacted> parameter
    38İzleyin
  • CVE-2024-43657When uploading new firmware, a shell script inside a firmware file is executed during its processing. This can be used to craft a custom firmware file with a cu
    37İzleyin

Düzeltme

Hangi sürüme geçmeli

Üretici, paket deposu ve Microsoft kayıtlarından derlenen düzeltme sürümleri. Yükseltmeden önce üreticinin notunu doğrulayın.

Bu kayıt için kayıtlı bir düzeltme sürümü yok. Üretici bildirimleri için referanslara bakın.

İstismar durumu

Bilinen kamuya açık istismar yok

Şu an kamuya açık bir istismar görülmedi. Bu, güvende olduğunuz anlamına gelmez; yalnızca eşiğin biraz daha yüksek olduğunu gösterir.

Araştırma bağlamı

Pentester ve araştırmacı için: saldırı profili, puan anlaşmazlığı, zaman çizelgesi, yama commit’leri, kredi, varyant ve zincir adayları, bug bounty kapsamı. Hepsi mevcut veriden türetilir; istismar kodu içermez.

Zaman çizelgesi

Yayından bugüne: kavram kanıtı, Metasploit modülü, CISA KEV ve düzeltme kaydı. Tarihler kaynakların bildirdiği tarihlerdir.

Yayın dışında tarihli olay yok.

EPSS son 120 gün

FIRST EPSS günlük puanı; yalnızca 0,01 ve üstü değişimler kaydedilir (adım grafiği).

Yama ve commit bağlantıları

Referanslardaki commit, PR ve diff adresleri. Patch-diff ve varyant avı için başlangıç noktası; istismar değil, düzeltmedir.

Referanslarda commit ya da PR bağlantısı yok.

CNA kaydında adı geçen bulan, bildiren ve analistler. Ada tıkla, aynı araştırmacının diğer kayıtlarını gör.

Varyant adayları

Aynı üründe aynı zafiyet sınıfı, 18 ay içinde. Yama kök nedeni kapatmadıysa kardeş hata burada olur.

Gece hesaplanan ilişki yok.

Zincir adayları

Aynı üründe kimlik doğrulama atlatma ile yetki isteyen bir açık kısa aralıkla yayımlanmış: birlikte kimlik doğrulamasız bir yola dönüşebilir.

—

Bug bounty kapsamı

Bilinen herkese açık program yok.

Kaynak: bounty-targets-data (HackerOne, Bugcrowd, Intigriti, YesWeHack herkese açık listeleri).

Teknik detay

Saldırı koşulları

  • Sisteme yerel erişimi olan biri tetikleyebilir.
  • Yönetici yetkisi gerekir.
  • Kullanıcının bir şey yapması gerekmez.
  • Özel bir koşul gerekmez; tekrarlanabilir.

Başarılı olursa

Gizlilik
Bütünlük
Erişilebilirlik
Saldırı vektörü
Yerel
Karmaşıklık
Düşük
Gereken yetki
Yüksek
Kullanıcı etkileşimi
Gerekmez
Kapsam
P

CVSS vektörü

CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:X/RE:X/U:X

nvd-secondary

Saldırı bağlamı

Bu zafiyet sınıfının (CWE) MITRE CAPEC saldırı desenleri ve ATT&CK teknikleri. Tespit kuralı ve tehdit avı için başlangıç noktası.

Bu CWE için MITRE'de CAPEC/ATT&CK eşlemesi yok.

Değişiklik günlüğü

Bu kayıtta izlenen alanlarda henüz değişiklik kaydı yok. Skor, KEV, istismar olgunluğu ve düzeltme durumu değiştiğinde burada görünür.

Referanslar

Üretici bildirimleri ve resmî kayıtlar. İstismar/PoC bağlantıları bilinçli olarak dışarıda bırakıldı.

Tüm kayıtlar