A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl.
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
- Yayın
- 12 Ara 2019
- Güncelleme
- 16 Haz 2026
- EPSS
- %0,5 · 43. yüzdelik
- CWE
- CWE-749
Takip etmek için giriş yap · Takip ettiğin kayıt KEV’e girer, istismarı çıkar ya da güncellenirse bildirim alırsın.
Rapor araçları
Aksiyon skoru
27
İzleyin
Şimdilik düşük öncelik.
- CVSS
- 27 / 40 · 6.8 / 10
- CISA KEV
- 0 / 30 · Listede değil
- EPSS
- 0 / 30 · %0,5
Noroxi analizi
Bu kayıt için henüz Noroxi analizi yok
Veritabanındaki yüz binlerce zafiyetin tamamına elle analiz yazmıyoruz; bu dürüst olmazdı. Öne çıkan ve sahada etkisi olan zafiyetler için mekanizma, tespit ve kapatma adımlarını ekibimiz yazıyor.
Bu ürünü kullanıyoruz, yardım isteyinEtkilenen sistemler
| Üretici | Ürün | CPE |
|---|---|---|
| siemens | simatic s7-1200 firmware | cpe:2.3:o:siemens:simatic_s7-1200_firmware |
| siemens | simatic s7-1200 | cpe:2.3:h:siemens:simatic_s7-1200 |
| siemens | s7-200 smart firmware | cpe:2.3:o:siemens:s7-200_smart_firmware |
| siemens | s7-200 smart | cpe:2.3:h:siemens:s7-200_smart |
| siemens | simatic s7-200 smart cpu st20 firmware | cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st20_firmware |
| siemens | simatic s7-200 smart cpu st20 | cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st20 |
| siemens | simatic s7-200 smart cpu st30 firmware | cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st30_firmware |
| siemens | simatic s7-200 smart cpu st30 | cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st30 |
| siemens | simatic s7-200 smart cpu st40 firmware | cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st40_firmware |
| siemens | simatic s7-200 smart cpu st40 | cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st40 |
| siemens | simatic s7-200 smart cpu st60 firmware | cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st60_firmware |
| siemens | simatic s7-200 smart cpu st60 | cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st60 |
ve 20 kayıt daha
Etkilenen sürümler
NVD sürüm aralıkları (katalogdaki ürünler için). Stack’ine sürümle eklersen eşleşme bunlarla yapılır.
- siemens s7-200 smart firmwaretüm sürümler
- siemens simatic s7-1200 firmwaretüm sürümler
- siemens simatic s7-200 smart cpu cr20s firmware2.3.0 dahil
- siemens simatic s7-200 smart cpu cr30s firmware2.3.0 dahil
- siemens simatic s7-200 smart cpu cr40 firmware2.2.2 dahil
- siemens simatic s7-200 smart cpu cr40s firmware2.3.0 dahil
- siemens simatic s7-200 smart cpu cr60 firmware2.2.2 dahil
- siemens simatic s7-200 smart cpu cr60s firmware2.3.0 dahil
- siemens simatic s7-200 smart cpu sr20 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu sr30 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu sr40 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu sr60 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu st20 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu st30 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu st40 firmware2.5.0 dahil
- siemens simatic s7-200 smart cpu st60 firmware2.5.0 dahil
Üreticinin bildirdiği sürümler
Kaydı açan otorite (siemens) tarafından bildirilen etkilenen sürüm aralıkları. NVD'nin CPE analizinden bağımsızdır ve genellikle ondan önce gelir.
Siemens AG SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
- All versionsetkilenir
Siemens AG SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants)
- All versionsetkilenir
Siemens AG SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)
- All versions with Function State (FS) < 11etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)
- All versions <= V2.3.0 and Function State (FS) <= 3etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)
- All versions <= V2.3.0 and Function State (FS) <= 3etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)
- All versions <= V2.2.2 and Function State (FS) <= 8etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)
- All versions <= V2.3.0 and Function State (FS) <= 3etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)
- All versions <= V2.2.2 and Function State (FS) <= 10etkilenir
Siemens AG SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)
- All versions <= V2.3.0 and Function State (FS) <= 3etkilenir
Siemens AG SIMATIC S7-200 SMART CPU family
- All versionsetkilenir
Siemens AG SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)
- All versions <= V2.5.0 and Function State (FS) <= 11etkilenir
Siemens AG SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)
- All versions <= V2.5.0 and Function State (FS) <= 10etkilenir
Aynı üründe
siemens: tüm kayıtlarAynı birincil ürünün en yüksek skorlu diğer kayıtları.
- CVE-2013-2780Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via32İzleyin
- CVE-2013-0700Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via32İzleyin
- CVE-2018-13815A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6).31İzleyin
- CVE-2012-3040Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inje18İzleyin
- CVE-2012-3037The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate,17İzleyin
Düzeltme
Hangi sürüme geçmeli
Üretici, paket deposu ve Microsoft kayıtlarından derlenen düzeltme sürümleri. Yükseltmeden önce üreticinin notunu doğrulayın.
Bu kayıt için kayıtlı bir düzeltme sürümü yok. Üretici bildirimleri için referanslara bakın.
İstismar durumu
Bilinen kamuya açık istismar yok
Şu an kamuya açık bir istismar görülmedi. Bu, güvende olduğunuz anlamına gelmez; yalnızca eşiğin biraz daha yüksek olduğunu gösterir.
Araştırma bağlamı
Pentester ve araştırmacı için: saldırı profili, puan anlaşmazlığı, zaman çizelgesi, yama commit’leri, kredi, varyant ve zincir adayları, bug bounty kapsamı. Hepsi mevcut veriden türetilir; istismar kodu içermez.
Zaman çizelgesi
Yayından bugüne: kavram kanıtı, Metasploit modülü, CISA KEV ve düzeltme kaydı. Tarihler kaynakların bildirdiği tarihlerdir.
Yayın dışında tarihli olay yok.
FIRST EPSS günlük puanı; yalnızca 0,01 ve üstü değişimler kaydedilir (adım grafiği).
Yama ve commit bağlantıları
Referanslardaki commit, PR ve diff adresleri. Patch-diff ve varyant avı için başlangıç noktası; istismar değil, düzeltmedir.
Referanslarda commit ya da PR bağlantısı yok.
Kredi
Tüm araştırmacılarCNA kaydında adı geçen bulan, bildiren ve analistler. Ada tıkla, aynı araştırmacının diğer kayıtlarını gör.
CNA kaydında kredi yok.
Varyant adayları
Aynı üründe aynı zafiyet sınıfı, 18 ay içinde. Yama kök nedeni kapatmadıysa kardeş hata burada olur.
Gece hesaplanan ilişki yok.
Zincir adayları
Aynı üründe kimlik doğrulama atlatma ile yetki isteyen bir açık kısa aralıkla yayımlanmış: birlikte kimlik doğrulamasız bir yola dönüşebilir.
—
Bug bounty kapsamı
Bilinen herkese açık program yok.
Kaynak: bounty-targets-data (HackerOne, Bugcrowd, Intigriti, YesWeHack herkese açık listeleri).
Ulusal bildirim (Siber Güvenlik Başkanlığı / USOM)
Bu kaydı anan resmi güvenlik bildirimleri; çözüm önerisi kurumun sayfasında.
- TR-19-308 · 10 Ara 2019(Siemens Endüstriyel Ürünler Zafiyeti)
- TR-19-270 · 17 Kas 2019(Siemens Endüstriyel Ürünler Zafiyeti)
Teknik detay
Saldırı koşulları
- Cihaza fiziksel erişim gerekir.
- Hesap ya da parola gerekmez.
- Kullanıcının bir şey yapması gerekmez.
- Özel bir koşul gerekmez; tekrarlanabilir.
Başarılı olursa
- Gizlilik
- yüksek · veriler okunabilir
- Bütünlük
- yüksek · veri ya da yapılandırma değiştirilebilir
- Erişilebilirlik
- yüksek · hizmet durdurulabilir
- Saldırı vektörü
- Fiziksel
- Karmaşıklık
- Düşük
- Gereken yetki
- Yok
- Kullanıcı etkileşimi
- Gerekmez
- Kapsam
- Değişmez
- Gizlilik etkisi
- Yüksek
- Bütünlük etkisi
- Yüksek
- Erişilebilirlik etkisi
- Yüksek
Zayıflık sınıfı (CWE)
CWE-749 · Exposed Dangerous Method or FunctionCVSS vektörü
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd-primary
Saldırı bağlamı
Bu zafiyet sınıfının (CWE) MITRE CAPEC saldırı desenleri ve ATT&CK teknikleri. Tespit kuralı ve tehdit avı için başlangıç noktası.
Saldırı desenleri (CAPEC)
ATT&CK teknikleri
—
Değişiklik günlüğü
Bu kayıtta izlenen alanlarda henüz değişiklik kaydı yok. Skor, KEV, istismar olgunluğu ve düzeltme durumu değiştiğinde burada görünür.
Referanslar
Üretici bildirimleri ve resmî kayıtlar. İstismar/PoC bağlantıları bilinçli olarak dışarıda bırakıldı.