The HPE-provided Windows firmware installer for certain Gen9, Gen8, G7,and G6 HPE servers allows local disclosure of privileged information.

The HPE-provided Windows firmware installer for certain Gen9, Gen8, G7,and G6 HPE servers allows local disclosure of privileged information. This issue was resolved in previously provided firmware updates as follows. The HPE Windows firmware installer was updated in the system ROM updates which also addressed the original Spectre/Meltdown set of vulnerabilities. At that time, the Windows firmware installer was also updated in the versions of HPE Integrated Lights-Out 2, 3, and 4 (iLO 2, 3, and 4) listed in the security bulletin. The updated HPE Windows firmware installer was released in the system ROM and HPE Integrated Lights-Out (iLO) releases documented in earlier HPE Security Bulletins: HPESBHF03805, HPESBHF03835, HPESBHF03831. Windows-based systems that have already been updated to the system ROM or iLO versions described in these security bulletins require no further action.

OrtaCVSS 5.5 · v3.0—İstismar yok Düzeltme kaydı yok
Yayın
3 Ara 2018
Güncelleme
16 Haz 2026
EPSS
%0,7 · 50. yüzdelik
CWE
—
Bu CVE’yi takip et

Takip etmek için giriş yap · Takip ettiğin kayıt KEV’e girer, istismarı çıkar ya da güncellenirse bildirim alırsın.

Rapor araçları

JSON

Aksiyon skoru

22

İzleyin

Şimdilik düşük öncelik.

CVSS
22 / 40 · 5.5 / 10
CISA KEV
0 / 30 · Listede değil
EPSS
0 / 30 · %0,7

Etkilenen sistemler

ÜreticiÜrün
hpintegrated lights-out 2 firmware
hpintegrated lights-out 2
hpproliant gen6 server
hpintegrated lights-out 3 firmware
hpintegrated lights-out
hpproliant gen7 server
hpintegrated lights-out 4 firmware
hpproliant gen8 server
hpproliant xl750f gen9 server firmware
hpproliant xl750f gen9 server
hpproliant xl740f gen9 server firmware
hpproliant xl740f gen9 server

ve 188 kayıt daha

Etkilenen sürümler

NVD sürüm aralıkları (katalogdaki ürünler için). Stack’ine sürümle eklersen eşleşme bunlarla yapılır.

  • hp integrated lights-out 2 firmware2.33 öncesi
  • hp integrated lights-out 3 firmware1.90 öncesi
  • hp integrated lights-out 4 firmware2.60 öncesi
  • hp proliant bl280c g6 server bladefirmware2018.05.21 öncesi
  • hp proliant bl2x220c g6 server blade firmware2018.05.21 öncesi
  • hp proliant bl2x220c g7 server blade firmware2018.05.21 öncesi
  • hp proliant bl420c gen8 server firmware2018.01.22 öncesi
  • hp proliant bl460c g6 server blade firmware2018.05.21 öncesi
  • hp proliant bl460c g7 server blade firmware2018.05.21 öncesi
  • hp proliant bl460c gen8 server blade firmware2018.01.22 öncesi
  • hp proliant bl460c gen9 server blade firmware2.56_01-22-2018 öncesi
  • hp proliant bl465c g7 server blade firmware2018.03.14 öncesi
  • hp proliant bl465c gen8 (amd) firmware2018.03.14 öncesi
  • hp proliant bl490c g6 server blade firmware2018.05.21 öncesi
  • hp proliant bl490c g7 server blade firmware2018.05.21 öncesi
  • hp proliant bl620c g7 server blade firmware2018.05.21 öncesi
  • hp proliant bl660c gen8 server blade firmware2018.01.22 öncesi
  • hp proliant bl660c gen9 server firmware2.56_01-22-2018 öncesi
  • hp proliant bl680c g7 server blade firmware2018.05.21 öncesi
  • hp proliant bl685c g7 server blade (amd) firmware2018.03.14 öncesi

Üreticinin bildirdiği sürümler

Kaydı açan otorite (hpe) tarafından bildirilen etkilenen sürüm aralıkları. NVD'nin CPE analizinden bağımsızdır ve genellikle ondan önce gelir.

  • Hewlett Packard Enterprise Windows firmware installer for Gen9, Gen8, G7,and G6 HPE servers

    • Only the Windows based firmware installers for the following products. HPE Integrated Lights-Out 2 (iLO 2) Firmware for ProLiant G6 Servers - Prior to v2.33, HPE Integrated Lights-Out 3 (iLO 3) Firmwaetkilenir

Aynı üründe

hp: tüm kayıtlar

Aynı birincil ürünün en yüksek skorlu diğer kayıtları.

  • CVE-2014-7876Unspecified vulnerability in HP Integrated Lights-Out (iLO) firmware 2 before 2.27 and 4 before 2.03 and iLO Chassis Management (CM) firmwar
    44Planlayın
  • CVE-2017-8979Security vulnerabilities in the HPE Integrated Lights-Out 2 (iLO 2) firmware could be exploited remotely to allow authentication bypass, cod
    40Planlayın
  • CVE-2014-2601The server in HP Integrated Lights-Out 2 (aka iLO 2) 2.23 and earlier allows remote attackers to cause a denial of service via crafted HTTPS
    32İzleyin
  • CVE-2015-2106Unspecified vulnerability in HP Integrated Lights-Out (iLO) firmware 2 before 2.27, 3 before 1.82, and 4 before 2.10 allows remote attackers
    26İzleyin

Düzeltme

Hangi sürüme geçmeli

Üretici, paket deposu ve Microsoft kayıtlarından derlenen düzeltme sürümleri. Yükseltmeden önce üreticinin notunu doğrulayın.

Bu kayıt için kayıtlı bir düzeltme sürümü yok. Üretici bildirimleri için referanslara bakın.

İstismar durumu

Bilinen kamuya açık istismar yok

Şu an kamuya açık bir istismar görülmedi. Bu, güvende olduğunuz anlamına gelmez; yalnızca eşiğin biraz daha yüksek olduğunu gösterir.

Araştırma bağlamı

Pentester ve araştırmacı için: saldırı profili, puan anlaşmazlığı, zaman çizelgesi, yama commit’leri, kredi, varyant ve zincir adayları, bug bounty kapsamı. Hepsi mevcut veriden türetilir; istismar kodu içermez.

Zaman çizelgesi

Yayından bugüne: kavram kanıtı, Metasploit modülü, CISA KEV ve düzeltme kaydı. Tarihler kaynakların bildirdiği tarihlerdir.

Yayın dışında tarihli olay yok.

EPSS son 120 gün

FIRST EPSS günlük puanı; yalnızca 0,01 ve üstü değişimler kaydedilir (adım grafiği).

Yama ve commit bağlantıları

Referanslardaki commit, PR ve diff adresleri. Patch-diff ve varyant avı için başlangıç noktası; istismar değil, düzeltmedir.

Referanslarda commit ya da PR bağlantısı yok.

CNA kaydında adı geçen bulan, bildiren ve analistler. Ada tıkla, aynı araştırmacının diğer kayıtlarını gör.

CNA kaydında kredi yok.

Varyant adayları

Aynı üründe aynı zafiyet sınıfı, 18 ay içinde. Yama kök nedeni kapatmadıysa kardeş hata burada olur.

Gece hesaplanan ilişki yok.

Zincir adayları

Aynı üründe kimlik doğrulama atlatma ile yetki isteyen bir açık kısa aralıkla yayımlanmış: birlikte kimlik doğrulamasız bir yola dönüşebilir.

—

Bug bounty kapsamı

Bilinen herkese açık program yok.

Kaynak: bounty-targets-data (HackerOne, Bugcrowd, Intigriti, YesWeHack herkese açık listeleri).

Teknik detay

Saldırı koşulları

  • Sisteme yerel erişimi olan biri tetikleyebilir.
  • Düşük yetkili bir hesap yeterli.
  • Kullanıcının bir şey yapması gerekmez.
  • Özel bir koşul gerekmez; tekrarlanabilir.

Başarılı olursa

Gizlilik
yüksek · veriler okunabilir
Bütünlük
yok
Erişilebilirlik
yok
Saldırı vektörü
Yerel
Karmaşıklık
Düşük
Gereken yetki
Düşük
Kullanıcı etkileşimi
Gerekmez
Kapsam
Değişmez
Gizlilik etkisi
Yüksek
Bütünlük etkisi
Yok
Erişilebilirlik etkisi
Yok

Zayıflık sınıfı (CWE)

—

CVSS vektörü

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

nvd-primary

Saldırı bağlamı

Bu zafiyet sınıfının (CWE) MITRE CAPEC saldırı desenleri ve ATT&CK teknikleri. Tespit kuralı ve tehdit avı için başlangıç noktası.

Bu CWE için MITRE'de CAPEC/ATT&CK eşlemesi yok.

Noroxi analizi

Bu kayıt için henüz Noroxi analizi yok

385 binden fazla zafiyetin tamamına elle analiz yazmıyoruz; bu dürüst olmazdı. Öne çıkan ve sahada etkisi olan zafiyetler için mekanizma, tespit ve kapatma adımlarını ekibimiz yazıyor.

Bu ürünü kullanıyoruz, yardım isteyin

Değişiklik günlüğü

Bu kayıtta izlenen alanlarda henüz değişiklik kaydı yok. Skor, KEV, istismar olgunluğu ve düzeltme durumu değiştiğinde burada görünür.

Referanslar

Tüm kayıtlar