IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) R
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
- Published
- Jun 5, 2018
- Updated
- Jun 16, 2026
- EPSS
- 0.4% · 28th percentile
- CWE
- CWE-121
Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.
Report tools
Action score
32
Monitor
Low priority for now.
- CVSS
- 32 / 40 · 8.2 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.4%
Noroxi analysis
No Noroxi analysis for this record yet
We don't hand-write analysis for the hundreds of thousands of vulnerabilities in the database; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.
We use this product, ask for helpAffected systems
| Vendor | Product | CPE |
|---|---|---|
| philips | intellivue mp2 firmware | cpe:2.3:o:philips:intellivue_mp2_firmware |
| philips | intellivue mp2 | cpe:2.3:h:philips:intellivue_mp2 |
| philips | intellivue x2 firmware | cpe:2.3:o:philips:intellivue_x2_firmware |
| philips | intellivue x2 | cpe:2.3:h:philips:intellivue_x2 |
| philips | intellivue mp30 firmware | cpe:2.3:o:philips:intellivue_mp30_firmware |
| philips | intellivue mp30 | cpe:2.3:h:philips:intellivue_mp30 |
| philips | intellivue mp50 firmware | cpe:2.3:o:philips:intellivue_mp50_firmware |
| philips | intellivue mp50 | cpe:2.3:h:philips:intellivue_mp50 |
| philips | intellivue mp70 firmware | cpe:2.3:o:philips:intellivue_mp70_firmware |
| philips | intellivue mp70 | cpe:2.3:h:philips:intellivue_mp70 |
| philips | intellivue np90 firmware | cpe:2.3:o:philips:intellivue_np90_firmware |
| philips | intellivue np90 | cpe:2.3:h:philips:intellivue_np90 |
and 24 more
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- philips avalon fetal/maternal monitors fm20 firmwareall versions
- philips avalon fetal/maternal monitors fm30 firmwareall versions
- philips avalon fetal/maternal monitors fm40 firmwareall versions
- philips avalon fetal/maternal monitors fm50 firmwareall versions
- philips intellivue mp2 firmwareall versions
- philips intellivue mp30 firmwareall versions
- philips intellivue mp50 firmwareall versions
- philips intellivue mp70 firmwareall versions
- philips intellivue mx100 firmwareall versions
- philips intellivue mx400 firmwareall versions
- philips intellivue mx450 firmwareall versions
- philips intellivue mx500 firmwareall versions
- philips intellivue mx550 firmwareall versions
- philips intellivue mx700 firmwareall versions
- philips intellivue mx800 firmwareall versions
- philips intellivue np90 firmwareall versions
- philips intellivue x2 firmwareall versions
- philips intellivue x3 firmwareall versions
Versions reported by the vendor
Affected version ranges reported by the assigning authority (icscert). Independent of NVD's CPE analysis and usually ahead of it.
ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors
- The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX40affected
Same product
philips: all recordsOther highest-scoring records for the same primary product.
- CVE-2018-10597IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) R33Monitor
- CVE-2018-10599IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) R21Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
No credits in the CNA record.
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
No nightly-computed relations.
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
—
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
Technical details
Attack conditions
- Someone on the same network segment can trigger it.
- No account or password is required.
- No user action is required.
- Special conditions such as timing or configuration are required.
If successful
- Confidentiality
- high · data can be read
- Integrity
- low · data or configuration can be modified
- Availability
- high · the service can be disrupted
Impact can extend beyond the vulnerable component (scope changes).
- Attack vector
- Adjacent
- Attack complexity
- High
- Privileges required
- None
- User interaction
- None
- Scope
- Changed
- Confidentiality impact
- High
- Integrity impact
- Low
- Availability impact
- High
Weakness class (CWE)
CWE-121 · Stack-based Buffer OverflowCVSS vector
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H
nvd-primary
Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
MITRE has no CAPEC/ATT&CK mapping for this CWE.
Change log
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Vendor advisories and official records. Exploit/PoC links are deliberately left out.