A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
- Published
- Dec 10, 2024
- Updated
- Jun 17, 2026
- EPSS
- 0.2% · 11th percentile
- CWE
- CWE-502
Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.
Report tools
Action score
33
Monitor
Low priority for now.
- CVSS
- 33 / 40 · 8.4 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 0.2%
CISA SSVC decision
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
Vulnrichment: CISA's decision-tree inputs.
CNA vs NVD score
- NVD
- —
- CNA · siemens
- 7.8
- NVD has not scored this yet; the score shown is the CNA’s.
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
The score given by the assigning authority versus NVD’s independent score. A gap means the severity is contested.
Noroxi analysis
No Noroxi analysis for this record yet
We don't hand-write analysis for the hundreds of thousands of vulnerabilities in the database; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.
We use this product, ask for helpAffected systems
—
Versions reported by the vendor
Affected version ranges reported by the assigning authority (siemens). Independent of NVD's CPE analysis and usually ahead of it.
Siemens SIMATIC S7-PLCSIM V16
- all versionsaffected
Siemens SIMATIC S7-PLCSIM V17
- all versionsaffected
Siemens SIMATIC STEP 7 Safety V16
- all versionsaffected
Siemens SIMATIC STEP 7 Safety V17
- before V17 Update 9affected
Siemens SIMATIC STEP 7 Safety V18
- all versionsaffected
Siemens SIMATIC STEP 7 Safety V19
- before V19 Update 4affected
Siemens SIMATIC STEP 7 V16
- all versionsaffected
Siemens SIMATIC STEP 7 V17
- before V17 Update 9affected
Siemens SIMATIC STEP 7 V18
- all versionsaffected
Siemens SIMATIC STEP 7 V19
- before V19 Update 4affected
Siemens SIMATIC WinCC Unified V16
- all versionsaffected
Siemens SIMATIC WinCC Unified V17
- before V17 Update 9affected
Same product
siemens: all recordsOther highest-scoring records for the same primary product.
- CVE-2023-32736A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V1628Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
No credits in the CNA record.
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
- CVE-2023-3273628 days apartA vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V1628Monitor
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
—
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
Technical details
Attack conditions
- Someone with local access to the system can trigger it.
- No account or password is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- Integrity
- Availability
- Attack vector
- Local
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- A
- Scope
- X
Weakness class (CWE)
CWE-502 · Deserialization of Untrusted DataCVSS vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
nvd-secondary
Root cause
Data received over the network is deserialized into the language’s native object format without verifying its source. Code paths inside the object can be triggered during deserialization.
The bug in code
The whole CWE-502 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
payload = sock.recv(65536)job = pickle.loads(payload)Fixed
payload = sock.recv(65536)if not hmac.compare_digest(sign(payload), header_sig): raise PermissionError("invalid signature")job = JobSchema.validate(json.loads(payload))Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
ATT&CK techniques
—
Change log
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Vendor advisories and official records. Exploit/PoC links are deliberately left out.