A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
Noroxi assessment
Priority: Monitor (action score 31/100)
- The sources we track (CISA KEV, Exploit-DB, Metasploit, Nuclei, GitHub) show no public exploit code or exploitation in the wild.
- Probability of exploitation in the next 30 days: 2.5% (FIRST EPSS); higher than 84.6% of all records.
- Anyone who can reach it over the internet can trigger it. No account or password is required. No user action is required. No special conditions are required; it is repeatable.
- According to CISA the attack is automatable: targets can be found by mass scanning.
- According to the record, no fixed version is available yet.
Low priority for now. Update when a fix is released; follow the vendor's advisory.
Generated automatically from the record's data: CVSS (NVD and CNA), CISA KEV and SSVC, FIRST EPSS, exploit sources, fixed versions. How we calculate it
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
- Published
- May 12, 2021
- Updated
- Jun 16, 2026
- EPSS
- 2.6% · 85th percentile
- CWE
- CWE-400
Report tools
Action score
31
Monitor
Low priority for now.
- CVSS
- 30 / 40 · 7.5 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 1 / 30 · 2.6%
CISA SSVC decision
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
Vulnrichment: CISA's decision-tree inputs.
Get told when this record changes
- Not in KEV: no record of exploitation in the wild
- No public exploit code on record
- No fixed version yet
If any of these changes, we'll tell you in the daily email digest.
Running WordPress? Scan your site free with WP Lens
Noroxi analysis
What does it mean in your environment?
The assessment above is generated automatically from the record's data; it doesn't know your environment. Our team verifies on your systems whether this vulnerability is actually exploitable and which mitigation is enough.
We use this product, ask for helpAffected systems
Is your version affected?
Pick the product and type the version you run. It's compared with this record's version ranges in your browser; the version isn't sent anywhere.
| Vendor | Product | CPE |
|---|---|---|
| siemens | simatic wincc runtime advanced | cpe:2.3:a:siemens:simatic_wincc_runtime_advanced |
| siemens | sinamics sh150 firmware | cpe:2.3:o:siemens:sinamics_sh150_firmware |
| siemens | sinamics sh150 | cpe:2.3:h:siemens:sinamics_sh150 |
| siemens | sinamics sm150i firmware | cpe:2.3:o:siemens:sinamics_sm150i_firmware |
| siemens | sinamics sm150i | cpe:2.3:h:siemens:sinamics_sm150i |
| siemens | sinamics gh150 firmware | cpe:2.3:o:siemens:sinamics_gh150_firmware |
| siemens | sinamics gh150 | cpe:2.3:h:siemens:sinamics_gh150 |
| siemens | sinamics gl150 firmware | cpe:2.3:o:siemens:sinamics_gl150_firmware |
| siemens | sinamics gl150 | cpe:2.3:h:siemens:sinamics_gl150 |
| siemens | sinamics gm150 firmware | cpe:2.3:o:siemens:sinamics_gm150_firmware |
| siemens | sinamics gm150 | cpe:2.3:h:siemens:sinamics_gm150 |
| siemens | sinamics sl150 firmware | cpe:2.3:o:siemens:sinamics_sl150_firmware |
and 23 more
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- siemens simatic hmi comfort outdoor panels 15" firmwarebefore 16
- siemens simatic hmi comfort outdoor panels 15" firmwarebefore 15.1
- siemens simatic hmi comfort outdoor panels 15" firmware15.1
- siemens simatic hmi comfort outdoor panels 15" firmware16
- siemens simatic hmi comfort outdoor panels 7" firmwarebefore 15.1
- siemens simatic hmi comfort outdoor panels 7" firmwarebefore 16
- siemens simatic hmi comfort outdoor panels 7" firmware15.1
- siemens simatic hmi comfort outdoor panels 7" firmware16
- siemens simatic hmi comfort panels 22" firmwarebefore 15.1
- siemens simatic hmi comfort panels 22" firmwarebefore 16
- siemens simatic hmi comfort panels 22" firmware15.1
- siemens simatic hmi comfort panels 22" firmware16
- siemens simatic hmi comfort panels 4" firmwarebefore 15.1
- siemens simatic hmi comfort panels 4" firmwarebefore 16
- siemens simatic hmi comfort panels 4" firmware15.1
- siemens simatic hmi comfort panels 4" firmware16
- siemens simatic hmi ktp mobile panels ktp400f firmwarebefore 15.1
- siemens simatic hmi ktp mobile panels ktp400f firmwarebefore 16
- siemens simatic hmi ktp mobile panels ktp400f firmware15.1
- siemens simatic hmi ktp mobile panels ktp400f firmware16
Versions reported by the vendor
Affected version ranges reported by the assigning authority (siemens). Independent of NVD's CPE analysis and usually ahead of it.
Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- All versions < V15.1 Update 6affected
Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants)
- All versions < V16 Update 4affected
Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)
- All versions < V15.1 Update 6affected
Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants)
- All versions < V16 Update 4affected
Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
- All versions < V15.1 Update 6affected
Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
- All versions < V16 Update 4affected
Siemens SIMATIC WinCC Runtime Advanced V15
- All versions < V15.1 Update 6affected
Siemens SIMATIC WinCC Runtime Advanced V16
- All versions < V16 Update 4affected
Siemens SINAMICS GH150
- All versionsaffected
Siemens SINAMICS GL150 (with option X30)
- All versionsaffected
Siemens SINAMICS GM150 (with option X30)
- All versionsaffected
Siemens SINAMICS SH150
- All versionsaffected
Same product
siemens: all recordsOther highest-scoring records for the same primary product.
- CVE-2021-27384A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.40Plan
- CVE-2021-27386A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.31Monitor
- CVE-2021-27383A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.31Monitor
- CVE-2021-25662A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.30Monitor
- CVE-2021-25661A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.30Monitor
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
No credits in the CNA record.
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
No nightly-computed relations.
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
—
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- No account or password is required.
- No user action is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- none
- Integrity
- none
- Availability
- high · the service can be disrupted
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality impact
- None
- Integrity impact
- None
- Availability impact
- High
Weakness class (CWE)
CWE-400 · Uncontrolled Resource ConsumptionCVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvd-primary
Root cause
Code that parses nested structures sets no depth or size limit. A small input can turn into a disproportionate processing load.
The bug in code
The whole CWE-400 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
function expand(node) { return node.children.map(expand);}Fixed
const MAX_DEPTH = 32;function expand(node, depth = 0) { if (depth > MAX_DEPTH) throw new Error("too deep"); return node.children.map((c) => expand(c, depth + 1));}Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Change log
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Show all references (2 more)Show less
Vendor advisories and official records. Exploit/PoC links are deliberately left out.