Skip to content
Noroxi
CVE-2020-6963· NVD / CVE Program· CNA icscert

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.

CriticalCVSS 10.0 · v3.1—No exploit No fix recorded
Published
Jan 24, 2020
Updated
Jun 16, 2026
EPSS
2.7% · 86th percentile
Follow this CVE

Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.

Report tools

JSON

Action score

41

Plan

Add it to your regular patch cycle.

CVSS
40 / 40 · 10.0 / 10
CISA KEV
0 / 30 · Not listed
EPSS
1 / 30 · 2.7%

Noroxi analysis

No Noroxi analysis for this record yet

We don't hand-write analysis for the hundreds of thousands of vulnerabilities in the database; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.

We use this product, ask for help

Affected systems

VendorProduct
gehealthcareapexpro telemetry server firmware
gehealthcareapexpro telemetry server
gehealthcarecarescape central station mai700 firmware
gehealthcarecarescape central station mai700
gehealthcarecarescape central station mas700 firmware
gehealthcarecarescape central station mas700
gehealthcareclinical information center mp100d firmware
gehealthcareclinical information center mp100d
gehealthcareclinical information center mp100r firmware
gehealthcareclinical information center mp100r
gehealthcarecarescape telemetry server mp100r firmware
gehealthcarecarescape telemetry server mp100r

Affected versions

NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.

  • gehealthcare apexpro telemetry server firmwareup to 4.2 inclusive
  • gehealthcare carescape central station mai700 firmware1.0
  • gehealthcare carescape central station mas700 firmware1.0
  • gehealthcare carescape telemetry server mp100r firmwareup to 4.2 inclusive
  • gehealthcare clinical information center mp100d firmware4.0
  • gehealthcare clinical information center mp100d firmware5.0
  • gehealthcare clinical information center mp100r firmware4.0
  • gehealthcare clinical information center mp100r firmware5.0

Versions reported by the vendor

Affected version ranges reported by the assigning authority (icscert). Independent of NVD's CPE analysis and usually ahead of it.

  • n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors

    • ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server, v4.2 & prior,Clinical Information Center,v4.X& 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Staffected

Other highest-scoring records for the same primary product.

  • CVE-2020-6966In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X
    41Plan
  • CVE-2020-6962In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X
    41Plan
  • CVE-2020-6961In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X
    40Plan
  • CVE-2020-6965In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X
    39Monitor
  • CVE-2020-6964In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X
    34Monitor

Remediation

Which version to upgrade to

Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.

No fix version is recorded for this entry. Check the references for vendor advisories.

Exploit status

No known public exploit

No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.

Research context

For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.

Timeline

From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.

No dated events beyond publication.

EPSS, last 120 days

FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).

Patch and commit links

Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.

No commit or PR link among the references.

Finders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.

No credits in the CNA record.

Variant candidates

Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.

No nightly-computed relations.

Chain candidates

An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.

—

Bug bounty scope

No known public program.

Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).

Technical details

Attack conditions

  • Anyone who can reach it over the internet can trigger it.
  • No account or password is required.
  • No user action is required.
  • No special conditions are required; it is repeatable.

If successful

Confidentiality
high · data can be read
Integrity
high · data or configuration can be modified
Availability
high · the service can be disrupted

Impact can extend beyond the vulnerable component (scope changes).

Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Changed
Confidentiality impact
High
Integrity impact
High
Availability impact
High

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

nvd-primary

Root cause

For convenience in support or manufacturing, an account that is identical on every device is embedded in the software. Credentials learned from one device work on all of them.

A representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.

Vulnerable

ts
const SUPPORT_USER = "support";const SUPPORT_PASS = "hardcoded-password";

Fixed

ts
const creds = await provisioning.deviceCredentials(deviceId);if (creds.mustRotate) await forcePasswordChange(deviceId);

Attack context

MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.

Change log

No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.

References

All records