Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.

HighCVSS 7.2 · v4.0—No exploit No fix recorded

Noroxi analysis

No Noroxi analysis for this record yet

We don't hand-write analysis for the hundreds of thousands of vulnerabilities in the database; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.

We use this product, ask for help
Published
Jun 2, 2026
Updated
Jul 22, 2026
EPSS
0.2% · 8th percentile
Follow this CVE

Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.

Report tools

JSON

Action score

28

Monitor

Low priority for now.

CVSS
28 / 40 · 7.2 / 10
CISA KEV
0 / 30 · Not listed
EPSS
0 / 30 · 0.2%

CISA SSVC decision

Exploitation
none
Automatable
no
Technical impact
partial

Vulnrichment: CISA's decision-tree inputs.

CNA vs NVD score

NVD
—
CNA · VulnCheck
7.2
NVD has not scored this yet; the score shown is the CNA’s.

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N

The score given by the assigning authority versus NVD’s independent score. A gap means the severity is contested.

Affected systems

—

Versions reported by the vendor

Affected version ranges reported by the assigning authority (VulnCheck). Independent of NVD's CPE analysis and usually ahead of it.

  • Dräger SC 6002XL

    • SC 6002XLaffected
  • Dräger SC 7000

    • SC 7000affected
  • Dräger SC6802XL

    • SC6802XLaffected
  • Dräger SC8000

    • SC8000affected
  • Dräger SC90000 XL

    • SC90000 XLaffected

Other highest-scoring records for the same primary product.

  • CVE-2019-25720Dräger SC Monitoring Devices DoS via Malformed Network Packet
    28Monitor

Remediation

Which version to upgrade to

Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.

No fix version is recorded for this entry. Check the references for vendor advisories.

Exploit status

No known public exploit

No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.

Research context

For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.

Timeline

From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.

No dated events beyond publication.

EPSS, last 120 days

FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).

Patch and commit links

Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.

No commit or PR link among the references.

Finders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.

Variant candidates

Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.

No nightly-computed relations.

Chain candidates

An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.

—

Bug bounty scope

No known public program.

Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).

Technical details

Attack conditions

  • Someone on the same network segment can trigger it.
  • No account or password is required.
  • No user action is required.
  • No special conditions are required; it is repeatable.

If successful

Confidentiality
Integrity
Availability
Attack vector
Adjacent
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
X

CVSS vector

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

nvd-secondary

Root cause

For convenience in support or manufacturing, an account that is identical on every device is embedded in the software. Credentials learned from one device work on all of them.

A representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.

Vulnerable

ts
const SUPPORT_USER = "support";const SUPPORT_PASS = "hardcoded-password";

Fixed

ts
const creds = await provisioning.deviceCredentials(deviceId);if (creds.mustRotate) await forcePasswordChange(deviceId);

Attack context

MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.

Change log

No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.

References

All records