A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
Noroxi analysis
No Noroxi analysis for this record yet
We don't hand-write analysis for the hundreds of thousands of vulnerabilities in the database; that wouldn't be honest. For notable, high-impact vulnerabilities our team writes the mechanism, detection and remediation steps.
We use this product, ask for help- Published
- Jan 16, 2020
- Updated
- Jun 16, 2026
- EPSS
- 1.4% · 71th percentile
- CWE
- CWE-306
Sign in to follow · You’ll be notified if a followed record enters KEV, gets an exploit or is updated.
Report tools
Action score
34
Monitor
Low priority for now.
- CVSS
- 34 / 40 · 8.6 / 10
- CISA KEV
- 0 / 30 · Not listed
- EPSS
- 0 / 30 · 1.4%
Affected systems
| Vendor | Product | CPE |
|---|---|---|
| siemens | scalance x-200rna firmware | cpe:2.3:o:siemens:scalance_x-200rna_firmware |
| siemens | scalance x-200rna | cpe:2.3:h:siemens:scalance_x-200rna |
| siemens | scalance x204rna firmware | cpe:2.3:o:siemens:scalance_x204rna_firmware |
| siemens | scalance x204rna | cpe:2.3:h:siemens:scalance_x204rna |
| siemens | scalance x-300 firmware | cpe:2.3:o:siemens:scalance_x-300_firmware |
| siemens | scalance x-300 | cpe:2.3:h:siemens:scalance_x-300 |
| siemens | scalance xr-300wg firmware | cpe:2.3:o:siemens:scalance_xr-300wg_firmware |
| siemens | scalance xr-300wg | cpe:2.3:h:siemens:scalance_xr-300wg |
| siemens | scalance xr-300 firmware | cpe:2.3:o:siemens:scalance_xr-300_firmware |
| siemens | scalance xr-300 | cpe:2.3:h:siemens:scalance_xr-300 |
| siemens | scalance x408-2 firmware | cpe:2.3:o:siemens:scalance_x408-2_firmware |
| siemens | scalance x408-2 | cpe:2.3:h:siemens:scalance_x408-2 |
and 2 more
Affected versions
NVD version ranges (for catalog products). Add the product to your stack with a version and matching uses these.
- siemens scalance x-200rna firmwareall versions
- siemens scalance x-300 firmwarebefore 4.1.3
- siemens scalance x204rna firmwareall versions
- siemens scalance x408-2 firmwarebefore 4.1.3
- siemens scalance xr-300 firmwarebefore 4.1.3
- siemens scalance xr-300wg firmwarebefore 4.1.3
- siemens siplus net csm 1277 firmwarebefore 4.1.3
Versions reported by the vendor
Affected version ranges reported by the assigning authority (siemens). Independent of NVD's CPE analysis and usually ahead of it.
Siemens SCALANCE X204RNA (HSR)
- All versions < V3.2.7affected
Siemens SCALANCE X204RNA (PRP)
- All versions < V3.2.7affected
Siemens SCALANCE X204RNA EEC (HSR)
- All versions < V3.2.7affected
Siemens SCALANCE X204RNA EEC (PRP)
- All versions < V3.2.7affected
Siemens SCALANCE X204RNA EEC (PRP/HSR)
- All versions < V3.2.7affected
Siemens SCALANCE X302-7 EEC (230V, coated)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (230V)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (24V, coated)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (24V)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (2x 230V, coated)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (2x 230V)
- All versions < V4.1.3affected
Siemens SCALANCE X302-7 EEC (2x 24V, coated)
- All versions < V4.1.3affected
Remediation
Which version to upgrade to
Fix versions compiled from the vendor, package registries and Microsoft. Verify the vendor's note before upgrading.
No fix version is recorded for this entry. Check the references for vendor advisories.
Exploit status
No known public exploit
No public exploit has been observed yet. That doesn't mean you're safe, only that the bar is a little higher.
Research context
For pentesters and researchers: attack profile, score disagreement, timeline, patch commits, credits, variant and chain candidates, bug bounty scope. All derived from existing data; no exploit code.
Timeline
From publication to today: proof of concept, Metasploit module, CISA KEV and fix record. Dates are as reported by the sources.
No dated events beyond publication.
FIRST EPSS daily score; only changes of 0.01 or more are recorded (step chart).
Patch and commit links
Commit, PR and diff links among the references. A starting point for patch-diffing and variant hunting; fixes, not exploits.
No commit or PR link among the references.
Credits
All researchersFinders, reporters and analysts named in the CNA record. Click a name for that researcher’s other records.
No credits in the CNA record.
Variant candidates
Same product, same weakness class, within 18 months. If the patch missed the root cause, the sibling bug is here.
No nightly-computed relations.
Chain candidates
An authentication bypass and a privilege-requiring bug in the same product, published close together: combined they may become an unauthenticated path.
—
Bug bounty scope
No known public program.
Source: bounty-targets-data (public HackerOne, Bugcrowd, Intigriti, YesWeHack listings).
Technical details
Attack conditions
- Anyone who can reach it over the internet can trigger it.
- No account or password is required.
- No user action is required.
- No special conditions are required; it is repeatable.
If successful
- Confidentiality
- low · data can be read
- Integrity
- high · data or configuration can be modified
- Availability
- low · the service can be disrupted
- Attack vector
- Network
- Attack complexity
- Low
- Privileges required
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality impact
- Low
- Integrity impact
- High
- Availability impact
- Low
Weakness class (CWE)
CWE-306 · Missing Authentication for Critical FunctionCVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L
nvd-primary
Root cause
A function added for development or support ships to production without authentication. It often relies on the assumption that it is “only reachable from the internal network.”
The bug in code
The whole CWE-306 classA representative example of this vulnerability class. Not the vendor's source code; it shows the faulty pattern and its fix.
Vulnerable
// Added for the support teamapp.post("/maintenance/reset", resetDevice);Fixed
if (config.maintenanceEnabled) { app.post( "/maintenance/reset", requireSession, requireRole("admin"), resetDevice );}Attack context
MITRE CAPEC attack patterns and ATT&CK techniques for this weakness class (CWE). A starting point for detection rules and threat hunting.
Attack patterns (CAPEC)
ATT&CK techniques
—
Change log
No changes recorded on tracked fields yet. Score, KEV, exploit maturity and fix status changes appear here.
References
Vendor advisories and official records. Exploit/PoC links are deliberately left out.