A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET I
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET 200eco PN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET 200eco PN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
- Yayın
- 14 Nis 2020
- Güncelleme
- 16 Haz 2026
- EPSS
- %1,7 · 77. yüzdelik
- CWE
- CWE-400
Takip etmek için giriş yap · Takip ettiğin kayıt KEV’e girer, istismarı çıkar ya da güncellenirse bildirim alırsın.
Rapor araçları
Aksiyon skoru
31
İzleyin
Şimdilik düşük öncelik.
- CVSS
- 30 / 40 · 7.5 / 10
- CISA KEV
- 0 / 30 · Listede değil
- EPSS
- 1 / 30 · %1,7
CNA ile NVD puanı
- NVD
- 7,5
- CNA · siemens
- 7,5
- uyumlu
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
Kaydı açan otoritenin puanı ile NVD’nin bağımsız puanı. İki puan arasındaki fark ciddiyetin tartışmalı olduğunu gösterir.
Etkilenen sistemler
| Üretici | Ürün | CPE |
|---|---|---|
| siemens | ktk ate530s firmware | cpe:2.3:o:siemens:ktk_ate530s_firmware |
| siemens | ktk ate530s | cpe:2.3:h:siemens:ktk_ate530s |
| siemens | sidoor atd430w firmware | cpe:2.3:o:siemens:sidoor_atd430w_firmware |
| siemens | sidoor atd430w | cpe:2.3:h:siemens:sidoor_atd430w |
| siemens | sidoor ate530s coated firmware | cpe:2.3:o:siemens:sidoor_ate530s_coated_firmware |
| siemens | sidoor ate530s coated | cpe:2.3:h:siemens:sidoor_ate530s_coated |
| siemens | sidoor ate531s firmware | cpe:2.3:o:siemens:sidoor_ate531s_firmware |
| siemens | sidoor ate531s | cpe:2.3:h:siemens:sidoor_ate531s |
| siemens | simatic et 200sp open controller cpu 1515sp pc firmware | cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware |
| siemens | simatic et 200sp open controller cpu 1515sp pc | cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc |
| siemens | simatic et 200sp open controller cpu 1515sp pc2 firmware | cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware |
| siemens | simatic et 200sp open controller cpu 1515sp pc2 | cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2 |
ve 53 kayıt daha
Etkilenen sürümler
NVD sürüm aralıkları (katalogdaki ürünler için). Stack’ine sürümle eklersen eşleşme bunlarla yapılır.
- siemens ktk ate530s firmwaretüm sürümler
- siemens sidoor atd430w firmwaretüm sürümler
- siemens sidoor ate530s coated firmwaretüm sürümler
- siemens sidoor ate531s firmwaretüm sürümler
- siemens simatic et 200sp open controller cpu 1515sp pc firmware2.0 öncesi
- siemens simatic et 200sp open controller cpu 1515sp pc2 firmware2.0 öncesi
- siemens simatic et200mp im155-5 pn hf firmware4.2 dahil
- siemens simatic et200sp im155-6 mf hf firmwaretüm sürümler
- siemens simatic et200sp im155-6 pn ha firmwaretüm sürümler
- siemens simatic et200sp im155-6 pn hf firmware4.2 dahil
- siemens simatic et200sp im155-6 pn/2 hf firmware4.2 dahil
- siemens simatic micro-drive pdc firmwaretüm sürümler
- siemens simatic pn/pn coupler firmware4.2 dahil
- siemens simatic s7-15002.0 öncesi
- siemens simatic s7-1500 cpu 1511-1 pn firmware2.0 öncesi
- siemens simatic s7-1500 cpu 1511f-1 pn firmware2.0 öncesi
- siemens simatic s7-1500 cpu 1513-1 pn firmware2.0 öncesi
- siemens simatic s7-1500 cpu 1513f-1 pn firmware2.0 öncesi
- siemens simatic s7-1500 cpu 1515-2 pn firmware2.0 öncesi
- siemens simatic s7-1500 cpu 1515f-2 pn firmware2.0 öncesi
Üreticinin bildirdiği sürümler
Kaydı açan otorite (siemens) tarafından bildirilen etkilenen sürüm aralıkları. NVD'nin CPE analizinden bağımsızdır ve genellikle ondan önce gelir.
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200
- tüm sürümleretkilenir
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
- tüm sürümleretkilenir
Siemens KTK ATE530S
- tüm sürümleretkilenir
Siemens SIDOOR ATD430W
- tüm sürümleretkilenir
Siemens SIDOOR ATE530S COATED
- tüm sürümleretkilenir
Siemens SIDOOR ATE531S
- tüm sürümleretkilenir
Siemens SIMATIC ET 200AL IM 157-1 PN
- tüm sürümleretkilenir
Siemens SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
Siemens SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
Siemens SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
Siemens SIMATIC ET 200eco PN, DI 16x24VDC, M12-L
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
Siemens SIMATIC ET 200eco PN, DI 8x24VDC, M12-L
- V5.1.1 ve sonrası · V5.1.2 öncesietkilenir
Düzeltme
Hangi sürüme geçmeli
Üretici, paket deposu ve Microsoft kayıtlarından derlenen düzeltme sürümleri. Yükseltmeden önce üreticinin notunu doğrulayın.
Bu kayıt için kayıtlı bir düzeltme sürümü yok. Üretici bildirimleri için referanslara bakın.
İstismar durumu
Bilinen kamuya açık istismar yok
Şu an kamuya açık bir istismar görülmedi. Bu, güvende olduğunuz anlamına gelmez; yalnızca eşiğin biraz daha yüksek olduğunu gösterir.
Araştırma bağlamı
Pentester ve araştırmacı için: saldırı profili, puan anlaşmazlığı, zaman çizelgesi, yama commit’leri, kredi, varyant ve zincir adayları, bug bounty kapsamı. Hepsi mevcut veriden türetilir; istismar kodu içermez.
Zaman çizelgesi
Yayından bugüne: kavram kanıtı, Metasploit modülü, CISA KEV ve düzeltme kaydı. Tarihler kaynakların bildirdiği tarihlerdir.
Yayın dışında tarihli olay yok.
FIRST EPSS günlük puanı; yalnızca 0,01 ve üstü değişimler kaydedilir (adım grafiği).
Yama ve commit bağlantıları
Referanslardaki commit, PR ve diff adresleri. Patch-diff ve varyant avı için başlangıç noktası; istismar değil, düzeltmedir.
Referanslarda commit ya da PR bağlantısı yok.
Kredi
Tüm araştırmacılarCNA kaydında adı geçen bulan, bildiren ve analistler. Ada tıkla, aynı araştırmacının diğer kayıtlarını gör.
CNA kaydında kredi yok.
Varyant adayları
Aynı üründe aynı zafiyet sınıfı, 18 ay içinde. Yama kök nedeni kapatmadıysa kardeş hata burada olur.
Gece hesaplanan ilişki yok.
Zincir adayları
Aynı üründe kimlik doğrulama atlatma ile yetki isteyen bir açık kısa aralıkla yayımlanmış: birlikte kimlik doğrulamasız bir yola dönüşebilir.
—
Bug bounty kapsamı
Bilinen herkese açık program yok.
Kaynak: bounty-targets-data (HackerOne, Bugcrowd, Intigriti, YesWeHack herkese açık listeleri).
Teknik detay
Saldırı koşulları
- İnternetten erişebilen herkes tetikleyebilir.
- Hesap ya da parola gerekmez.
- Kullanıcının bir şey yapması gerekmez.
- Özel bir koşul gerekmez; tekrarlanabilir.
Başarılı olursa
- Gizlilik
- yok
- Bütünlük
- yok
- Erişilebilirlik
- yüksek · hizmet durdurulabilir
- Saldırı vektörü
- Ağ
- Karmaşıklık
- Düşük
- Gereken yetki
- Yok
- Kullanıcı etkileşimi
- Gerekmez
- Kapsam
- Değişmez
- Gizlilik etkisi
- Yok
- Bütünlük etkisi
- Yok
- Erişilebilirlik etkisi
- Yüksek
Zayıflık sınıfı (CWE)
CWE-400 · Uncontrolled Resource ConsumptionCVSS vektörü
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvd-primary
Kök neden
İç içe yapıları çözümleyen kod derinlik ya da boyut sınırı koymuyor. Küçük bir girdi orantısız işlem yüküne dönüşebilir.
Hatanın kod karşılığı
CWE-400 sınıfının tamamıBu zafiyet sınıfının temsili örneği. Üreticinin kaynak kodu değildir; hatalı kalıbı ve düzeltmesini gösterir.
Hatalı
function expand(node) { return node.children.map(expand);}Düzeltilmiş
const MAX_DEPTH = 32;function expand(node, depth = 0) { if (depth > MAX_DEPTH) throw new Error("çok derin"); return node.children.map((c) => expand(c, depth + 1));}Saldırı bağlamı
Bu zafiyet sınıfının (CWE) MITRE CAPEC saldırı desenleri ve ATT&CK teknikleri. Tespit kuralı ve tehdit avı için başlangıç noktası.
Saldırı desenleri (CAPEC)
ATT&CK teknikleri
Noroxi analizi
Bu kayıt için henüz Noroxi analizi yok
385 binden fazla zafiyetin tamamına elle analiz yazmıyoruz; bu dürüst olmazdı. Öne çıkan ve sahada etkisi olan zafiyetler için mekanizma, tespit ve kapatma adımlarını ekibimiz yazıyor.
Bu ürünü kullanıyoruz, yardım isteyinDeğişiklik günlüğü
Bu kayıtta izlenen alanlarda henüz değişiklik kaydı yok. Skor, KEV, istismar olgunluğu ve düzeltme durumu değiştiğinde burada görünür.
Referanslar
- cert-portal.siemens.com/productcert/html/ssa-593272.html
- cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf
Üretici bildirimleri ve resmî kayıtlar. İstismar/PoC bağlantıları bilinçli olarak dışarıda bırakıldı.